EasyManuals Logo

IDEAL 61-605 User Manual

IDEAL 61-605
4 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
#61-605
Digital Multimeter
Instruction Manual
WARNING
Read First: Safety Information
Understand and follow operating instructions carefully.
Use the meter only as specified in this manual; other-
wise, the protection provided by the meter may be
impaired.
WARNING
To avoid possible electric shock, personal injury or death follow these guidelines:
Do not use if meter appears damaged. Visually inspect the meter to ensure
case is not cracked and back case is securely in place.
Inspect and replace leads if insulation is damaged, metal is exposed, or
probes are cracked. Pay particular attention to the insulation surrounding the
connectors.
Do not use meter if it operates abnormally as protection maybe impaired.
Do not use during electrical storms or in wet weather.
Do not use around explosive gas, dust, or vapor.
Do not apply more than the rated voltage to the meter.
Do not use without the battery and the back case properly installed.
Remove the test leads from the circuit prior to removing battery cap.
Do not attempt to repair this unit as it has no user-serviceable parts.
CAUTION
To protect yourself, think "Safety First":
Voltages exceeding 30VAC or 60VDC pose a shock hazard so use caution.
Use appropriate personal protective equipment such as safety glasses, face
shields, insulating gloves, insulating boots, and/or insulating mats.
Before each use:
- Perform a continuity test by touching the test leads together to verify the
functionality of the battery and test leads.
- Use the 3 Point Safety Method. (1) Verify meter operation by measuring a
known voltage. (2) Apply meter to circuit under test. (3) Return to the
known live voltage again to ensure proper operation.
Never ground yourself when taking electrical measurements.
Connect the black common lead to ground before applying the red test lead to
voltage. Disconnect the red test lead from the voltage first.
Always work with a partner.
When using the probes, keep fingers as far behind the probe tips as possible.
Features:
• Auto/manual ranging meter
• Measures AC/DC Voltage and Resistance
• Audible continuity
• Diode Test
• Data hold
• Auto Power Off
• Low Battery Indicator
• Compact case with built-in test leads
• Electronic overload protection on all ranges
MK
RANGE HOLD
AC/DC
Open case to access
test leads.
2
ND 4950-3 61-605 Instructions 10/27/06 9:32 AM Page 1
99 Washington Street
Melrose, MA 02176
Fax 781-665-0780
TestEquipmentDepot.com

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDEAL 61-605 and is the answer not in the manual?

IDEAL 61-605 Specifications

General IconGeneral
BrandIDEAL
Model61-605
CategoryMultimeter
LanguageEnglish