- 20 -
X
ND
O
M
bc
• Operation •
Operating elements
A - Safety light beam
B - Safety two-handed control system
clamping and cutting
C - Air table On-Off
D - Backgauge control
E - Foot pedal
F - Main switch
G - Hand-wheel for backgauge setting
H - Key switch
I - Backgauge
J - Side lay left and right
K - Clamp pressure adjustment
L - Paper knock-up block
Start machine
• Main switch F to position "I".
Start screen appears
The following functions are changeable:
Brightness
CM/INCH
Touchtone volume
Language
Display / status photocell
b green - red
Clamping pressure
c
• Press START M backgauge I moves
to the rear and searches for the reference
position, wait until a measurement
is shown in the display
D
7260 = 72.00 cm, 28.346 inches
• The DIN and free programmable
measurements are recallable with the
respective buttons
X.
Memory 1: A2, A3, A4, A5,
Memory 2: A6, A7, B3, B4
Memory 3:
Memory 4:
and in inch
Memory 1: 4¼“, 5 ½“, 7“, 8 ½“
Memory 2: 11“, 12“, 14“, 17“
Memory 3:
Memory 4: