EasyManuals Logo
Home>IDEAL>Boiler>COMBI ESP 24

IDEAL COMBI ESP 24 User Manual

IDEAL COMBI ESP 24
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #13 background imageLoading...
Page #13 background image
DISPLAY CODE ON THE BOILER DESCRIPTION ACTION
BCC activation fault Reset the appliance - if the boiler fails to operate then please
contact Ideal (if under warranty) or alternatively a Gas Safe
Registered Engineer if outside of the warranty period. In IE
contact a Registered Gas Installer (RGII).
BCC fault Check the correct BCC is fitted for the boiler, and securely
inserted into the slot at the front left of the PCB. (Identified by the
label on the BCC). If yes then replace the current BCC with a new
one correctly labelled for the boiler. If it is incorrect (turn off the
power) then insert correctly into PCB after switching power back
on restart the boiler.
Low water pressure Check system pressure is between 1 & 1.5bar on the pressure gauge.
If the boiler fails to operate then please contact Ideal (if under
warranty) or alternatively a Gas Safe Registered Engineer if outside
of the warranty period. In IE contact a Registered Gas Installer (RGII).
Flow temperature
overheat or no
water flow
Is the boiler and CH heating system filled and all isolation vales
and radiators open? If not then ll and vent the system and open
all isolation valves and restart the boiler. Check that the pumps are
rotating freely and the flow and return have a differential across the
boiler in excess of 30°C.
Flame loss 1. Check other gas appliances in the house are working to conrm a
supply is present in the property.
2. If other appliances do not work or there are no other appliances,
check the gas supply is on at the meter and/or pre payment meter
has credit. If the boiler fails to operate then please contact Ideal (if
under warranty) or alternatively a Gas Safe Registered Engineer if
outside of the warranty period. In IE contact a
Registered Gas Installer (RGII).
Fan fault Reset the appliance - if the boiler fails to operate then please
contact Ideal (if under warranty) or alternatively a Gas Safe
Registered Engineer if outside of the warranty period. In IE
contact a Registered Gas Installer (RGII).
Flow thermistor Reset the appliance - if the boiler fails to operate then please
contact Ideal (if under warranty) or alternatively a Gas Safe
Registered Engineer if outside of the warranty period. In IE
contact a Registered Gas Installer (RGII).
Return thermistor Reset the appliance - if the boiler fails to operate then please
contact Ideal (if under warranty) or alternatively a Gas Safe
Registered Engineer if outside of the warranty period. In IE
contact a Registered Gas Installer (RGII).
FAULT CODES.
13

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDEAL COMBI ESP 24 and is the answer not in the manual?

IDEAL COMBI ESP 24 Specifications

General IconGeneral
BrandIDEAL
ModelCOMBI ESP 24
CategoryBoiler
LanguageEnglish