49
HORIZONTAL
FLUE WITH
2 X 45° ELBOW.
NOTE:
Lengths are sum of all straight lengths
between outside edge of turret to outside
wall face.
Numbers of extension D packs give flexibility
of lengths of straight at either side of elbow.
Where extension D packs are cut to length,
flared end connector must be retained.
FLUE IDEAL
PART NO.
MAXIMUM STRAIGHT
FLUE LENGTH (MM)
Horizontal flue terminal (0.6m long)
+ 2 x Flue elbow 45° kit (60/100)
208171
203131
556
Telescopic B pack flue (0.6m long)
+ 2 x Flue elbow 45° kit (60/100)
208169
203131
484
Horizontal flue terminal (0.6m long)
+ 5 x Flue extension 1m (pack D)
+ 2 x Flue elbow 45° kit (60/100)
208171
5 x 203129
203131
5306 (35 max length 4.8m.
+ 2 x 45° elbow)
Telescopic B pack flue (0.6m long)
+ 5 x Flue extension 1m (pack D)
+ 2 x Flue elbow 45° kit (60/100)
208169
5 x 203129
203131
5234 (35 max length 4.8m.
+ 2 x 45° elbow)
Horizontal flue terminal (0.6m long)
+ 7 x Flue extension 1m (pack D)
+ 2 x Flue elbow 45° kit (60/100)
208171
7 x 203129
203131
7236 (30 max length 6.8m.
+ 2 x 45° elbow)
Telescopic B pack flue (0.6m long)
+ 7 x Flue extension 1m (pack D)
+ 2 x Flue elbow 45° kit (60/100)
208169
7 x 203129
203131
7134 (30 max length 6.8m.
+ 2 x 45° elbow)
Horizontal flue terminal (0.6m long)
+ 8 x Flue extension 1m (pack D)
+ 2 x Flue elbow 45° kit (60/100)
208171
8 x 203129
203131
7800 (12-24 models max length
7.8m. + 2 x 45° elbow)
Telescopic B pack flue (0.6m long)
+ 8 x Flue extension 1m (pack D)
+ 2 x Flue elbow 45° kit (60/100)
208169
8 x 203129
203131
7800 (12-24 models max length
7.8m. + 2 x 45° elbow