Do you have a question about the IDEAL icos HE30 and is the answer not in the manual?
Type | Combi |
---|---|
Output | 30 kW |
Fuel Type | Natural Gas |
Height | 700mm |
Mounting | Wall-mounted |
Max Working Pressure | 3 bar |
Wall-mounted, room-sealed, super efficient condensing boiler with automatic spark ignition and fan-assisted combustion.
Boiler installation must be by a CORGI registered installer in line with current regulations.
The appliance requires a 230V, 50Hz supply, fused at 3A, connected via a double-pole switch.
Key notes regarding casing fitment, compartment use, air grilles, and sealed components.
Required clearances for servicing: 165mm above, 150mm below, 15mm sides, 450mm front.
Step-by-step guide to lighting the boiler, ensuring electricity supply is OFF initially.
Displays for standby (0), heating (C), and frost protection (P). LED indicates ignition and running status.
Adjustable central heating radiator temperature via CH thermostat knob, max 82°C.
Procedure for short periods (switch off) and longer periods (switch off supply, drain system).
Recommendations for preventing frost during absence, using heating controls or draining the system.
Describes fault codes 'L:A' (overheat) and 'L:F' (flame failure) and reset procedures.
The condensate drain must not be blocked. Freezing can cause shutdown.
Advice on suspected gas leaks (do not use naked flame) and cleaning the appliance.
The appliance requires annual servicing by a CORGI registered installer or competent person.
Check power, programmer, room thermostat settings, and gas supply for no operation.
Check condensate pipe for blockages or freezing. Press reset button.
Indicates overheat condition. Press reset button. Contact installer if fault recurs.
Check if all radiators have thermostatic radiator valves fitted. Contact installer.