EasyManua.ls Logo

Idex MICROPUMP EagleDrive DEELE - User Manual

Default Icon
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
DOC No: PN 86880 REV A
EagleDrive™ DEMSE
EagleDrive™ DEELE
Without Enclosure
Without Enclosure
DEMSN
DEELN
EAGLEDRIVE
INSTALLATION, OPERATION AND
WARRANTY INFORMATION

Questions and Answers

  • T
    Tammy SmithAug 9, 2025
    Why my Idex DC Drives motor will not operate?
    • J
      James CowanAug 9, 2025
      If your Idex DC Drives motor isn't operating, first ensure that the correct voltage is applied to the motor power leads and check for any short circuits. Also, verify that the control power supply common is connected to the common lead. If the thermal limit is active, turn off the motor and allow it to cool. If the problem persists, reduce the motor load or improve cooling. If these steps don't resolve the issue, the motor may be damaged, consider contacting your Micropump Distributor or Micropump directly for a replacement.
  • K
    Kyle RussellAug 15, 2025
    What to do if there is no tachometer signal in Idex DC Drives?
    • D
      Deborah WilliamsAug 15, 2025
      If there's no tachometer signal in your Idex DC Drives, first ensure the motor has power by checking the voltage to the motor power leads and looking for short circuits. Verify the Tachometer Out lead is connected to the positive input of the frequency counter, and the frequency counter's common lead is connected to the motor's Common lead. Also, make sure the motor is running by ensuring proper voltage and control input are applied.
  • K
    Kenneth MillerAug 21, 2025
    How to fix cyclic noise or vibrations in Idex DC Drives?
    • P
      Philip DunnAug 21, 2025
      Cyclic noise or vibrations in Idex DC Drives can stem from several issues. Start by tightening the motor mounting bolts and the pump mounting bolts. If the foundation isn't rigid, relocate the motor. Check if the Tachometer Out lead is shorted to the FWD/REV lead, and if so, clear and isolate them. If the pump is worn, consider replacing or repairing it.
  • A
    Allison SnyderAug 27, 2025
    What to do if the Control Input lead is shorted in Idex DC Drives?
    • S
      samuelmurrayAug 27, 2025
      If your Idex DC Drives motor isn't operating, check if the Control Input lead is shorted. Clear and isolate the Control Input lead from the Tachometer Out lead and from the Common lead.
  • J
    Jeffrey RodriguezSep 2, 2025
    Why is my Idex DC Drives motor running in the wrong direction?
    • M
      Matthew RobertsSep 2, 2025
      If the Idex DC Drives motor runs in the wrong direction, the FWD/REV lead might be shorted to the Common lead. Clear and isolate the FWD/REV lead from the Common lead or shield, and check the leads for short circuits.

Summary

Standard Limited Warranty

Safety

Limits of Use

Installation in Explosive and Fire Danger Zones

Assembly

Bulkhead Mounting (DEELE Model)

Required EagleDrive Electrical Connections

Electrical Safety and Power Input

Outlines essential electrical safety practices, power supply requirements, and fuse recommendations for EagleDrive.

EagleDrive Electrical Connections (Continued)

Control Signal Inputs (Analog and PWM)

Details common ground requirements and specifications for analog DC and PWM speed control signal inputs.

4-20 mA Control Configuration

Manual Control Configuration

Other EagleDrive Electrical Connections

Fault Output

Fault Conditions and Remedies

Lists various fault signals, their causes, and recommended remedies for troubleshooting.

Operation

Maintenance

Troubleshooting

Motor Operation Issues

Addresses problems like motor not operating, noise, vibrations, and incorrect direction of rotation.

Signal and Wiring Issues

Covers troubleshooting for missing tachometer signals and improper wiring connections.

EagleDrive Lead Wire Assignments

EagleDrive Lead Wire Assignments (Continued)

Technical Specification

Model DEMSE Specifications

Lists detailed technical specifications for the EagleDrive DEMSE model, including dimensions and performance data.

Idex MICROPUMP EagleDrive DEELE Specifications

General IconGeneral
Power Supply24 VDC
CertificationsCE, RoHS
Drive TypeBrushless DC Motor
ModelEagleDrive DEELE
Max PressureUp to 100 psi
Operating Temperature5°C to 40°C
MaterialsPTFE