EasyManua.ls Logo

IEC E055-71520301 - Step #2 Remove & Replace Old Thermostat

IEC E055-71520301
19 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remove the cover of the old thermostat.
If it does not come off easily check for
screws.
Loosen the screws holding the thermostat
base or subbase to the wall and lift away.
Disconnect the wires from the old
thermostat. Tape the ends of the wires
as you disconnect them and mark them
with the letter of the terminal for easy
reconnection to the new thermostat.
Keep the old thermostat for reference
purposes until your new thermostat is
functioning properly.
STEP #2
REMOVE & REPLACE OLD THERMOSTAT
Note: This thermostat is strictly a low voltage control.
One or two E025-71520303 relay boards must be
installed to isolate the 24 volt wires from the line
voltages to the fan, and possibly the water valves.
(IF APPLICABLE)