iFAN 3IN1 PORTABLE AIRCON AIR CONDITIONER / FAN / DEHUMIDIFIER
IF9012
Question and Answer IconNeed help?

Do you have a question about the iFan IF9012 and is the answer not in the manual?

Overview

This document describes the IFAN 3IN1 Portable Air Conditioner, Model IF9012, which functions as an air conditioner, fan, and dehumidifier.

Function Description:

The IFAN IF9012 is a versatile 3-in-1 portable appliance designed for cooling, fanning, and dehumidifying indoor spaces. It is suitable for areas up to 400 sq ft and utilizes a climate-friendly refrigerant. The device offers various modes of operation to suit different environmental needs and user preferences.

Important Technical Specifications:

  • Model: IF9012
  • Rated Voltage: 220 – 240 V ~50 – 60 Hz
  • Power: 1340 W
  • Cooling Capacity: 12000 BTU
  • Air Flow Volume: 400 m³/hr
  • Dimensions: 420 x 360 x 720 mm
  • Weight: 30.7 kg (gross) / 27 kg (nett)
  • Cooling Area: 400 sq ft
  • Energy Efficiency Class: A (as indicated by the energy label)
  • Refrigerant: Climate-friendly refrigerant used.

Usage Features:

Installation:

Before initial use, the portable air conditioner must be kept upright for at least 2 hours. When moving the appliance, it should always be kept upright on a horizontal and dry surface.

  1. Exhaust Pipe Assembly: Screw the exhaust pipe assembly into the exhaust port on the rear panel. The exhaust pipe length is adjustable between 280 ~ 1500 mm. It is crucial not to distort the pipe or subject it to a turning angle greater than 45° to ensure proper ventilation and prevent overheating. Using extension tubes or different hoses is not recommended as it may cause malfunction.
  2. Window Sealing Plate Assembly: Half-open the window and mount the window sealing plate assembly horizontally or vertically. Components of the assembly can be adjusted to fit the window frame.
  3. Placement: Place the main body with the installed exhaust pipe assembly before the window, ensuring a minimum distance of 50 cm from walls or other objects to allow adequate air circulation.

Control Panel and Remote Control:

The appliance can be operated via an LED Control Panel on the unit or a Remote Control.

LED Control Panel Buttons:

  • TIMER: Sets the timer for appliance operation (1-24 hours). Press once to exit when ON, or to input when OFF.
  • FAN: Toggles between COOL, DEHUMIDIFY, and FAN modes.
  • UP/DOWN: Adjusts temperature or timer settings upwards/downwards.
  • MODE: In FAN or COOL Mode, toggles between HIGH, MIDDLE, or LOW wind speed. In DEHUMIDIFY Mode, wind speed is fixed at LOW.
  • POWER: Turns the appliance ON and OFF.
  • SLEEP (via simultaneous FAN and UP press on LED panel or SLEEP button on remote): Activates energy-saving operation in COOL mode only. Not available in DEHUMIDIFY or FAN modes.
  • FULL (indicator): Lights up and buzzer sounds when the internal water pan is full.

Remote Control Buttons:

  • DISPLAY: Shows current settings (temperature, timer, mode).
  • POWER: Turns the appliance ON and OFF.
  • TIMER: Sets the timer.
  • SWING: Swings the louvre (air outlet).
  • SLEEP: Activates energy-saving operation in COOL mode.
  • DOWN/UP: Adjusts temperature or timer settings.
  • MODE: Toggles between modes and wind speeds.
  • FAN: Toggles between modes.

Operating Modes:

  • COOL Mode: Provides cooling. Temperature and fan speed can be adjusted.
  • DEHUMIDIFY Mode: Removes moisture from the air. Wind speed is fixed at LOW in this mode.
  • FAN Mode: Circulates air without cooling. Fan speed can be adjusted.

Safety Functions:

  • Frost Protection Function: Automatically enters protection status if the exhaust pipe temperature is too low in COOL, DEHUMIDIFY, or SLEEP modes, reverting to normal operation when the temperature rises.
  • Automatic Defrosting: The appliance has an automatic defrosting function.
  • Compressor Protection Function: Features a 3-minute delay booting protection after the compressor is turned off to extend its service life.
  • Overflow Protection Function: Sounds an alarm and flashes the "FULL" indicator light when the water pan exceeds the warning level, stopping operation. The appliance resumes normal operation after the water is emptied.

Drainage:

  • Manual Drainage:
    1. Turn off the wall switch and unplug the power cable.
    2. Move the drainage pipe to a toilet or drainage area.
    3. Unscrew the drainage plug from the drainage hole. Water will flow out. The appliance can be tilted slightly backward to facilitate drainage.
    4. Securely re-attach the drainage plug and restart the appliance immediately to prevent condensate water from flowing onto the floor.
  • Continuous Drainage (optional, DEHUMIDIFY mode only):
    1. Turn off the wall switch and unplug the power cable.
    2. Unplug the rubber stopper from the continuous drainage hole.
    3. Insert a water pipe into the water outlet and direct the other end into a bucket for continuous water flow.

Maintenance Features:

Cleaning:

  • Surface Cleaning: Clean the appliance surface with a wet soft cloth. Avoid using chemicals like benzene, alcohol, or gasoline, as they can damage the surface.
  • Filter Screen Cleaning: Clean the filter screen every two weeks, or when it is clogged with dust and the appliance's effectiveness is reduced.
  • Upper Filter Screen Frame Cleaning:
    1. Clasp the wedging block of the EVA filter screen frame and force it down from the outside to remove it.
    2. Unscrew four screws fixing the EVA filter screen and the Rear Housing to remove the EVA filter screen.
    3. Wash the EVA filter screen in warm water with neutral detergent (around 40°C/104°F) and dry it in the shade after rinsing.

Storage Instructions (after Manual Drainage):

  1. Repeat manual drainage steps, then restart the appliance in COOL mode with LOW Wind Speed until the drainage pipe is dry before switching off.
  2. Turn off the wall switch and unplug the power cable. Wrap the power cable around the wrapping post.
  3. Remove the exhaust pipe. Cover the appliance and the exhaust pipe in separate plastic bags and store them in a dry place, out of reach of children, with dust control measures.
  4. Remove the battery from the remote control.

General Safety and Usage Guidelines:

  • Always read the manual carefully before installation, use, and maintenance.
  • Ensure the appliance is used only for its designed purpose.
  • Installation must follow manufacturer's instructions.
  • Check the integrity of the appliance and power cable before use. Do not operate if the compressor is damaged or the power cable is faulty.
  • Ensure voltage, frequency, and socket grounding are appropriate.
  • Avoid adapters or extension cables unless absolutely necessary and compliant with safety regulations.
  • Do not use external timers or unspecified remote controls.
  • Use only original components and accessories.
  • Keep packing materials away from children.
  • Do not use or store near heat sources or in explosive environments.
  • Ensure adequate clearance (at least 50 cm from back, left, right sides; 20 cm from top) for air circulation.
  • Do not place multiple portable socket outlets or power supplies at the bottom or rear.
  • Avoid placing near curtains or textiles.
  • Do not place the power cable on abrasive/sharp surfaces, under carpets, or in high-traffic areas.
  • Do not operate near open windows during rain or in humid environments like bathrooms.
  • Use and store indoors only, protected from weathering.
  • Clean exterior parts with warm water and detergent; ensure the compressor does not come into contact with water.
  • Ensure front grilles, air inlet, and air outlet are not damaged.
  • Place on a horizontal, stable, and dry surface.
  • Do not cover the appliance, obstruct air inlet/outlet, or insert objects/body parts during operation.
  • Avoid using insecticide sprays, aromatherapy oils, or flammable substances near the appliance.
  • Do not push buttons forcefully.
  • Do not use gasoline, thinner, or benzene for cleaning.
  • Do not leave unsupervised during operation.
  • Avoid touching with wet body parts; wear rubber-soled shoes.
  • Do not soak the appliance in water or other liquids.
  • Switch off and unplug firmly with dry hands before emptying, cleaning, or maintenance. Allow to cool for at least 30 minutes before storing.
  • In case of malfunction, switch off immediately and seek qualified assistance.
  • If smoke is observed, switch off immediately.
  • Not intended for commercial use, but for households and similar applications (staff kitchens, dormitories, hotels, B&Bs).
  • Can be used by children aged 8+ and persons with reduced capabilities under supervision. Children should not play with the appliance. Cleaning and maintenance by children only if 8+ and supervised. Keep out of reach of children under 8.

Troubleshooting:

The manual provides a detailed troubleshooting guide for common issues such as:

  • Appliance not responding (power cable, remote control batteries, overflow indicator).
  • Appliance functions but air is not cool enough (direct sunlight, open doors/windows, heat sources, clogged filter, blocked air inlet/outlet).
  • Compressor not working (overheat protection).
  • Appliance making noise (not on a flat surface).
  • Remote control not working (distance, alignment, dead batteries).
  • Error codes 'E1' (Pipe Temperature Sensor abnormal) and 'E2' (Room Temperature Sensor abnormal).

Warranty:

  • Two-year warranty against defective materials and manufacturing faults from the date of purchase.
  • Does not cover normal wear and tear, consumables, or maintenance costs.
  • Does not cover damage from misuse, accidents, negligence, alterations, or unauthorized repairs.
  • Repair and service are performed at PowerPac Electrical Pte Ltd. A transport fee applies for doorstep service.
  • Proof of purchase and warranty registration are required for service.
  • Warranty is void if the serial number is erased, defaced, or altered.
  • Warranty is void if defects are caused by pests, fire, lightning, natural disasters, pollution, abnormal voltage, or generator usage.
  • Valid in Singapore only.
  • Customer registration with original invoice/receipt is required. Failure to present documents may result in denial of service, with PowerPac having discretion to repair at the customer's expense.