COMCO IKARUS
Maintenance Manual C42 Series
MaintenanceManual C42-
Series_Issue_VII_18.02.2014.doc
Revison No.:1 56 from 107
No. Description
Inspection
Ref.
Chapter
Signature
every
50
hours
very
100
hours
16
Induction system
17
Check condition and attachment of the induction system hoses (C42
B / E only) and air filter attachment (C42 A), respectively
x x
18
Check condition of air filters and clean as required
Note:
The air filters in the C42 B / E are located in the induction system
hoses between the air plenum and the carburettor. The induction
system hoses must be dismantled in order that the air filters may be
inspected and serviced.
x
19
Check carburettor heating air flap (C42 B / E only) for freedom of
movement
x x
20 Fuel system
21
Visual inspection of connections and hoses for integrity, condition
(porosity), leaking and secure attachment
x x
22 Visual inspection of tank for leaking
x x
23 Check tank for inner cleanliness; clean as required
x
4.3.2.1
24 Check tank ventilation is free of obstacles (blow through)
x x
25 Check fuel filter for dirt; replace, if necessary
x x
26
Check electrical fuel pump for
- secure fitting of the cable connections
- secure fitting/leaking of line connections
- every 300 hours, check flow capacity
x x
4.3.2.2
27 Check fuel valve for freedom of movement
x x
28 Cooling system
29 Visual inspection of cooler condition and check for leaks
x x
30
Visual inspection of condition of heat exchanger and check for leaks
(C42 B / E only)
x x
31 Check cooling system for leaks
x x
32
Visual inspection of condition, porosity and secure attachment of
hoses; if necessary, replace damaged hoses and attachments and
loose clamps
x x
33
Check that the correct amount of coolant is in the reservoir; if
necessary, fill up with coolant
x x
34 Check coolant for oil; if applicable, find out and eliminate the cause
x x
35 Coolant change in accordance with Rotax maintenance manual in accordance with Rotax manual
36 Oil system
37 Check condition of oil cooler and for leaks (C42 A only)
x x