ATTENTION!
In the event that the machine operates with coin, coin or equivalent systems, the emergency stop device is not
present. The installer must provide and install an emergency stop device positioned remotely and connected to
each machine in the installation.
ATTENTION!
All washing machines are equipped with speed regulation and therefore equipped with a frequency variator: it is
specifically necessary to provide differential protection through a type B RCD device (sensitive to the average
current value).
ATTENTION!
The machinery must be protected by an appropriate circuit breaker of the magneto thermic type, installed
outside the machinery. The interrupting power must be at least 10 kA. The magnetic protection, i.e. against
short circuits, can alternatively be performed by means of an omni polar fuse disconnector, of the same size.
The characteristics of the flow rate of the circuit breaker, as well as the current In of the differential, are listed
in the table below.