11
Technical specication
Measurement range
Total pressure
-TA-SCOPE .................................................................................................................. max. 232 psi
-TA-SCOPEHP ............................................................................................................ max. 362 psi
Di󰀨erential pressure
-TA-SCOPE .....................................................................................................................0 - 72.5 psi
-TA-SCOPEHP ................................................................................................................0 - 145 psi
Recommended pressure range during ow measurements
-TA-SCOPE ................................................................................................................0.02 - 72.5 psi
-TA-SCOPEHP .............................................................................................................0.5 - 145 psi
Temperature liquid medium measurement ......................................................................-4 - +248°F
Measurement deviation
Di󰀨erential pressure
–TA-SCOPE .................................................. 0.015 psi or 1% of reading, whichever is the highest
–TA-SCOPEHP............................................. 0.029 psi or 1% of reading, whichever is the highest
Flow ............................................................................. asfordi󰀨erentialpressure+valvedeviation
Temperature ......................................................................................................................... <0.36°F
Ambient temperature
During operation ...........................................................................................................+32 - +104°F
During charging ............................................................................................................+32 - +104°F
During storage *...............................................................................................................-4 - +150°F
*) Do not leave water in the sensor when there is a risk of freezing
Humidity
Ambient humidity ..........................................................................................................max. 90%RH
Sealing
Handheld unit (in wireless mode) ............................................................................................. IP 64
Dp sensor unit DpS-Visio (in wireless mode) ........................................................................... IP 64
Digital temperature sensor ....................................................................................................... IP 65
IP6X = dust tight
IPX4 = protected against splashing water
IPX5 = protected against water jets
Multi-charger
Input voltage ................................................................................................................ 100-240 VAC
Input frequency ................................................................................................................... 50-60 Hz
Outputvoltage ........................................................................................................................ 5 VDC
Outputcurrent......................................................................................................................6800 mA
Connectors ........................................................................................................ EU,UK,US,AU/NZ
Technical speciactions valid at an altitude of max. 6560 ft.