Breakage of the central heating delivery probe (B1) stops boiler operation.
Breakage of the d.h.w. probe (B2) is signalled by the flashing of LED 10 ( ), and the
boiler continues working in the d.h.w. mode.
Breakage of the NTC
probes
(B1 and B2)
After the burner switches off at the end of a request the combustion chamber is washed
and the fan works for 30 seconds.
Sealed chamber
post-ventilation
To prevent the water-gas exchanger overheating, if the NTC delivery probe (B1) measures
a boiler temperature higher than 90°C, the fan starts working and continues until the
temperature drops below 85 °C.
Fan for delivery
overheating
To prevent the water-gas exchanger from overheating, at the end of each central heating, an-
tifreeze or “chimneysweep” request the circulator (M1) keeps working for 150 seconds.
Post-circulation circulator