H
Hector MercerAug 8, 2025
How to fix no ignition block in Immergas Maior Eolo 24 4E?
- SShane JonesAug 8, 2025
If your Immergas Boiler fails to ignite, try pressing the Reset button (5).
How to fix no ignition block in Immergas Maior Eolo 24 4E?
If your Immergas Boiler fails to ignite, try pressing the Reset button (5).
What to do if Immergas Maior Eolo 24 4E safety thermostat is blocked?
If the safety thermostat is blocked due to over-temperature in your Immergas Boiler, press the Reset key (5).
What to do if Immergas Maior Eolo 24 4E Boiler is blocked for maximum time, gas valve opening?
If your Immergas Boiler is blocked because the gas valve remains open longer than normal without the boiler switching on, press the Reset button (5).
What to do if Immergas Maior Eolo 24 4E Boiler is blocked due to loss of continuous flame signal?
If your Immergas Boiler is blocked due to loss of continuous flame signal (occurs 6 times consecutively in 8.5 minutes), press the Reset button (5).
How to fix parasite flame in Immergas Maior Eolo 24 4E Boiler?
If you observe a parasite flame in your Immergas Boiler, possibly due to a leak on the detection circuit or an anomaly in the flame control unit, try to reset the boiler.
How to fix insufficient circulation in Immergas Maior Eolo 24 4E Boiler?
If your Immergas Boiler has insufficient circulation due to low circulation or a blocked pump, check for closed interception devices and free the pump.
How to restore Remote Control communication with Immergas Boiler?
If your Immergas Boiler loses Remote Control communication, remove and re-apply voltage to the boiler.