    Patricia SalasAug 11, 2025
    What to do if my Immergas VICTRIX ZEUS SUPERIOR 25 smells of gas?
    • E
      Erica GrahamAug 11, 2025
      If you notice a smell of gas from your Immergas Boiler, it is likely caused by leakage from gas circuit pipe-lines. You should check the sealing efficiency of the gas intake circuit.
  • M
    michaelrobinsonAug 15, 2025
    Why is my Immergas VICTRIX ZEUS SUPERIOR 25 making abnormal noises?
    • K
      Kristen ChanAug 15, 2025
      Abnormal noises in your Immergas Boiler system are often due to air present in the system. To address this, check the opening of the cap of the air vent valve. Also, ensure the system pressure and expansion vessel pre-charge values are within the set limits. The factory-set pressure values of the expansion vessel must be 1.0 bar, and the value of system pressure must be between 1 and 1.2 bar.
  • A
    Aaron HarrisonAug 20, 2025
    What to do if my Immergas VICTRIX ZEUS SUPERIOR 25 Boiler has irregular combustion or is noisy?
    • C
      crystal70Aug 20, 2025
      If your Immergas Boiler is experiencing irregular combustion or unusual noisiness, this could be due to a dirty burner, a clogged primary heat exchanger, incorrect combustion parameters, or an incorrectly installed intake-exhaust terminal. You should check these components to resolve the issue.
  • B
    Beth FrancisAug 26, 2025
    What to do if my Immergas VICTRIX ZEUS SUPERIOR 25 Boiler has a rotor seized?
    • L
      latashawoodAug 26, 2025
      If the rotor in your Immergas Boiler is seized, carefully act on the screw in the middle of the head to manually release the crankshaft. Circulation starts up immediately after the rotor is released, and the LED switches from red to green after about 10 seconds.
  • T
    Timothy CunninghamAug 30, 2025
    What to do if my Immergas Boiler has non-optimal ignition?
    • S
      Shelley LopezAug 30, 2025
      If your Immergas Boiler experiences non-optimal ignition during the first ignitions of the burner (after calibration), the system automatically adjusts the burner ignition until the best ignition conditions are found.
  • Y
    yangelizabethSep 4, 2025
    What to do if my Immergas Boiler has low power supply voltage?
    • T
      tonyaharrisSep 4, 2025
      If your Immergas Boiler has a low power supply voltage, wait for the power supply voltage to rise. When the pump restarts, the LED will turn green again with a delay of about one second. Note that the flow rate decreases as the supply voltage decreases.