USING THE REFRIGERATOR AT HOME
- This model can be fed equally using 12-24V or mains power (110V - 240V AC).
- It is equipped with 2 sockets to connect the two different cables for DC respectively AC.
- The refrigerator is provided with automatic switch over from one kind of feeding to the other.
- Should both be present at the same time, the device will always set itself on mains power priority feeding
by 110V~240V AC.
WIRING SYSTEM
Compressor station
Functions and features.
This is an electronic device which has the function of piloting the motor of the compressor and carrying
out all the controls and electrical protection of the system .
Its main features are as follows :
a) Protection of the battery through automatic turning off of the compressor when the feeding voltage
reaches the minimum threshold .
The compressor will start up again automatically when the voltage goes back to normal values.
Note: these values have been measured at control unit input and/or on the DC socket.
Battery protection
(SWITCH POSITION)
Cut-out 12V Cut-in 12V Cut-out 24V Cut-in 24V
MED 10.1 11.4 22.3 23.7
HIGH 11.1 12.4 24.3 25.7
LOW 9.6 10.9 21.3 22.7
189A0471
MED
HIGH
LOW
15
15
DC12V/24V
DC12V/24V
FUSE
15A
50HZ/60HZ
AC110-120V/220-240V
VERSION WITH ELECTRONIC THERMOSTAT