J
James HarrisAug 12, 2025
How to fix Indel B TB 30 AM DRAWER if it does not cool and the compressor will not start?
- MMaria BensonAug 12, 2025
If your Indel B refrigerator isn't cooling and the compressor won't start, first ensure the electronic control unit is getting enough power and voltage, and check the fuse. See if the internal light works and if the compressor is receiving power. Inspect cables, lugs, and connectors. Confirm the battery is charging correctly. Test the thermostat by bridging T - C with a separate cable. If the compressor still doesn't start, the electronics are likely faulty and need replacement. If it starts with the bridge, replace the thermostat.