OFFSET
is the data which is used to align the temperature shown on the display with the actual internal
temperature. Adjustment for each offset can vary from -8 / +8.
After a few hours of refrigeration system operation, insert a digital thermometer (not included)
inside the compartment in the position where you wish to have a more precise temperature and
check that the temperature indicated on the display coincides with the temperature read on the
digital thermometer. If it does not coincide, change the Offset related to the temperature you wish
to reach inside the compartment until the temperature read on the display coincides with the
temperature indicated on the digital thermometer.
Offset Temperature Interval
1 T ≥ -6°C
2 -12°C ≤ T ≤ -7°C
3 T ≤ -13°C
DISPLAY ERRORS TABLE
Error Cause
E1 Insufcient voltage (Volts below the cut-in / cut-out value)
E2 Defective fan
E3 Control unit error or compressor blocked
E4
The refrigeration system is too loaded with gas and/or the compressor is
running at a number of revolutions that is too low
E5 Room temperature is too high
E6 Internal temperature sensor error