it with warm water and mild soap and by drying any water/condensation that may be encountered.
To keep the surface of the door in good conditions and intact, make sure that it is always dry and
clean.
In order to prevent damage to the electrical/mechanical components and/or the formation of
mould, when shutting off the refrigerator for extended periods of time it is necessary to wait for
the unit to defrost completely and to eliminate any condensation that may have formed inside.
The natural defrosting time can vary from a few minutes to several hours. In the wintertime and
when the refrigerator is shut off, the door should be left slightly ajar for ventilation and all power
disconnected.
LOW VOLTAGE PROTECTION
In order to prevent excessive battery depletion, a protection device shuts off the compressor in
case of insufcient voltage and turns it back on when the voltage in the system increases after the
batteries have been charged.
Battery Protection
Battery level
Digital
Display
12 Vdc 24 Vdc
Cut-Out
Comp. off
Cut-In
Comp. on
Cut-Out
Comp. off
Cut-In
Comp. on
Low
9.6 10.6 21.3 22.7
Medium
11.1 12.1 22.3 23.7
High
11.8 12.8
24.3 25.7
Warning!
Before switching on the unit, always make sure that the batteries are in optimal condition.