C100 - Replace filter on cooling fan of main and counter spindles
Orientation
The filters must be replaced regularly depending on the environmental conditions.
Whether air flow exists can quickly and easily be made visible by
attaching a thread at the opening of the air outlet.
Use only the original filters according to the spare or wear parts list!
Otherwise the machine is at risk of sustaining serious damage due to
overheating.
Requirement
A sufficient number of filters must be available.
Procedure
1. Remove side panels on the main and counter spindles.
2. Remove wire basket over the cooling fan.
3. Replace filter.
4. Clean air hoses of cooling fans. Disconnect air hoses and remove any
impurities. Here also clean the air inlet and outlet openings directly on the
spindle.
5. Reinstall all covers.
Maintenance Summary - 2.000 Operating hours
57
Maintenance Instructions
C100
LP1602.10091 - 05.06.2019