14
Battery charging
Using the charger
To charge your battery, plug in the charger in a well ventilated area which is free from
inflammable products, sources of ignition and damp. The ideal ambient temperature should
be between 50°F and 77°F.
1. Connect the power cord to the charger.
2. Connect the power cord to the mains outlet.
3. The charger initializes when it is powered on.
The status LED (1) alternates between red/green
and the wintering LED (2) lights for 3 seconds
4. When the LEDs turn off, the charger is ready
for use.
Charging the battery
Charging the batteries when the ambient temperature is below 32°F or above
104°F is strictly prohibited.
Neither the battery nor the charger should be covered, close to a heat source or to
inflammable products during charging. Do not obstruct the charger's ventilation fins.
1. Connect the battery to the charger's
output cable.
2. When the battery is connected, the
charger detects it and starts charging.,
The status LED
(1) flashes green.
3. Battery charged: the status LED
(1)
switches to steady green. The time to fully
charge an L100B battery is about 2h.
(1)
(2)
3
1
2