Cod. 710.0138.45.00 Rev04 – 02.2019
- EN -
DIRECT EXPANSION COMPRESSED AIR DRYERS
Operators Manual
Valid for 60 Hz dryers G version
D12IN-A
230/1/60
D25IN-A
D42IN-A
D54IN-A
D72IN
-
A
D108IN-A
D144IN-A
D180IN-A
D240IN-A
D300IN-A
D360IN-A
D480IN-A
D600IN-A
230/1/60 460/3/60
D780IN-A
380/3/60 460/3/60
D950IN-A

Questions and Answers

  • D
    David WilliamsAug 3, 2025
    Why is there low pressure in the line of my Ingersoll-Rand D12IN-A?
    • E
      edwardsamandaAug 3, 2025
      If you're experiencing low pressure in the line of your Ingersoll-Rand Dehumidifier, several factors could be the cause. First, ice might be forming in the evaporator. You should check the probe and the electronic control board; if the problem continues, consider replacing them. You may need to contact a service center to check the gas charge. Alternatively, ensure the compressed air inlet/outlet is properly connected, the connecting tubing isn't clogged, and no valves are closed. Also, inspect the filter's condition. If air flows continuously through the condensate drainage, the drainage solenoid valve might be jammed; try cleaning or replacing it.
  • A
    Anthony SmithAug 19, 2025
    What to do if low pressure persists in Ingersoll-Rand D12IN-A Dehumidifier D12-480IN-A or D600-950IN-A?
    • J
      Juan BennettAug 19, 2025
      For Ingersoll-Rand Dehumidifier model D12-480IN-A with low line pressure, first verify the condensate drainage times set on the electronic control board (C8 and C9). Then, check the signal from the control board. If the signal is continuous, it may be necessary to replace the control board. For model D600-950IN-A, inspect the no loss condensate drain and replace it if the issue persists.

Summary

1. GENERAL INFORMATION

1.1 Functional description

Explains how the compressed air dryer operates to remove moisture.

1.2 Safe use of the dryer

Outlines critical safety precautions for operating the air dryer.

2. INSTALLATION

2.1 Acceptance and transportation

Procedures for inspecting and handling the dryer upon delivery.

2.2 Installation site

Requirements for selecting an appropriate location for dryer installation.

2.3 Installation

Step-by-step guide for the physical installation of the dryer.

3. START UP

3.1 Control panel

Details the functions and components of the dryer's electronic control panel.

3.2 Before start up

Essential checks and preparations required before the initial dryer startup.

3.3 Start up

The procedure for powering on and starting the compressed air dryer.

4. MAINTENANCE, TROUBLESHOOTING AND DISMANTLING

4.1 Maintenance

Routine maintenance procedures and schedules for the air dryer.

4.2 Troubleshooting

Identifies common issues and provides solutions for dryer problems.

4.3 Dismantling

Instructions for safely disassembling the dryer.

ATTACHMENTS TO THIS MANUAL

A) Refrigerant circuit

Diagram illustrating the refrigerant system of the air dryer.

B) Electric circuit diagram

Electrical wiring diagrams for various dryer models.

C) Technical data sheet

Comprehensive specifications and performance data for the dryers.

D) Correction factors

Factors used to adjust dryer performance based on operating conditions.

E) Dryer dimensions

Physical dimensions and connection details for different dryer models.

F) Basic spare parts

List of essential spare parts with part numbers for easy identification.