Cod. 710.0138.45.00 Rev04 – 02.2019
- EN -
DIRECT EXPANSION COMPRESSED AIR DRYERS
Operators Manual
Valid for 60 Hz dryers G version
D12IN-A
230/1/60
D25IN-A
D42IN-A
D54IN-A
D72IN
-
A
D108IN-A
D144IN-A
D180IN-A
D240IN-A
D300IN-A
D360IN-A
D480IN-A
D600IN-A
230/1/60 460/3/60
D780IN-A
380/3/60 460/3/60
D950IN-A

Other manuals for Ingersoll-Rand D180IN-A

Questions and Answers

  • K
    kimberlykentAug 8, 2025
    Why is there low pressure in the line of my Ingersoll-Rand D180IN-A?
    • S
      Sarah EllisAug 8, 2025
      If you're experiencing low pressure in the line of your Ingersoll-Rand Dehumidifier, several factors could be the cause. First, ice might be forming in the evaporator. You should check the probe and the electronic control board; if the problem continues, consider replacing them. You may need to contact a service center to check the gas charge. Alternatively, ensure the compressed air inlet/outlet is properly connected, the connecting tubing isn't clogged, and no valves are closed. Also, inspect the filter's condition. If air flows continuously through the condensate drainage, the drainage solenoid valve might be jammed; try cleaning or replacing it.
  • C
    Christopher GriffinAug 21, 2025
    What to do if low pressure persists in Ingersoll-Rand D180IN-A Dehumidifier D12-480IN-A or D600-950IN-A?
    • B
      Brittany BruceAug 21, 2025
      For Ingersoll-Rand Dehumidifier model D12-480IN-A with low line pressure, first verify the condensate drainage times set on the electronic control board (C8 and C9). Then, check the signal from the control board. If the signal is continuous, it may be necessary to replace the control board. For model D600-950IN-A, inspect the no loss condensate drain and replace it if the issue persists.

Summary

GENERAL INFORMATION

Functional Description and Safe Use

Explains dryer operation and outlines essential safety precautions for use.

INSTALLATION

Site Selection and Procedures

Criteria for selecting location and steps for connecting the dryer.

START UP AND OPERATION

Control Panel and Start Sequence

Overview of control panel, keys, display, and step-by-step start-up guide.

MAINTENANCE AND TROUBLESHOOTING

Maintenance Schedule and Issue Resolution

Scheduled tasks, common issues, causes, and solutions for dryer problems.

REFRIGERANT CIRCUIT

Model Specific Diagrams

Diagrams illustrating refrigerant circuits for different dryer model ranges.

WIRING DIAGRAMS

Model Specific Wiring and Circuits

Electrical schematics for various dryer models, including power, control, and terminals.

DATA SHEET

CORRECTION FACTORS

Pressure and Temperature Adjustments

Factors for adjusting dryer performance based on operating conditions.

DRYER DIMENSIONS

BASIC SPARE PARTS

Ingersoll-Rand D180IN-A Specifications

General IconGeneral
ModelD180IN-A
BrandIngersoll-Rand
CategoryDehumidifier
Phase1
RefrigerantR410A
Water Removal Capacity180 pints/day
Capacity180 PPD