What to do if vessels do not switch over in Ingersoll-Rand Dehumidifier?
- AAndrea YangAug 26, 2025
If the vessels in your Ingersoll-Rand Dehumidifier do not switch over, there are several potential causes. The inlet valve V1 (V2) might not be opening, so you should check the electrical functioning of the solenoids and replace either the solenoid or the complete valve assembly. The printed circuit board (PCB) might not be functioning, so check the PCB and the fuse in the control cabinet. The vessel might not be pressurized, so check whether the depressurization valves are dirty and replace these if necessary; also, check the electrical functioning of the solenoids and replace either the solenoid or the complete valve assembly. Lastly, the regeneration orifice could be obstructed, so clean or replace it.