80447113
Revision A
July 2013
Save These Instructions
Contact-Cooled Rotary Screw Air Compressor
Installation, Operation and Maintenance
UP5 4, UP5 5, UP5 7, UP5 11c
UP6 5, UP6 7, UP6 10, UP6 15c
Installation, exploitation et maintenance
FR
Instalação, operação e manutenção
PT
Installation, Operation and Maintenance
EN
Instalación, operación y mantenimiento
ES
71113.13.16

Table of Contents

Questions and Answers

  • M
    mitchelltommyAug 2, 2025
    Why drain timer will not operate on my Ingersoll-Rand UP5 4 Air Compressor?
    • E
      Ellen KellyAug 2, 2025
      If the drain timer on your Ingersoll-Rand Air Compressor isn't working, first ensure it's receiving electrical power. If power is supplied, the timer itself may be malfunctioning and need replacement. A clogged port or strainer could also be the cause, so clean the valve and strainer. Additionally, a malfunctioning solenoid valve can prevent the timer from operating, so consider replacing the solenoid valve.
  • J
    Jessica BowmanAug 18, 2025
    What to do if the solenoid condensate valve will not close on my Ingersoll-Rand UP5 4?
    • Q
      qmorrisAug 18, 2025
      If the solenoid condensate valve on your Ingersoll-Rand Air Compressor won't close, it might be due to debris preventing the diaphragm from seating properly. Try removing the solenoid valve, disassembling it, cleaning all the parts, and then reassembling it. Also, a short in the electrical components could be the culprit. Inspect the power cord or timer and replace them if necessary.

Summary

Contact-Cooled Rotary Screw Air Compressor

Installation, Operation, and Maintenance Manual

Provides comprehensive instructions for installing, operating, and maintaining the compressor unit.

Safety Precautions

General Safety Instructions and User Responsibility

Emphasizes reading and following all safety instructions, labels, and making information accessible to others.

Installation and Handling Guidelines

Operating Procedures

General Operation and Control System Overview

Describes the compressor's general operation, air/coolant flow, and the automatic on-off load control system.

Automatic and Constant Speed Control Modes

Automatic Start & Stop Control System

Details on how the Automatic Start & Stop control functions based on receiver tank pressure.

Dual Control System Settings

Explanation of how to select between automatic start/stop and constant speed control using the auxiliary valve.

Control Panel Functions and Startup Procedures

Control Panel Components and Indicators

Identifies and explains the functions of the pressure gauge, hourmeter, buttons, and indicator lights.

Pre-Start Checks and Startup Sequence

Outlines essential visual checks, coolant level, valve operation, and power checks before starting.

Maintenance Schedule and Routine Tasks

Troubleshooting Common Issues

Ingersoll-Rand UP5 4 Specifications

General IconGeneral
BrandIngersoll-Rand
ModelUP5 4
CategoryAir Compressor
LanguageEnglish