EasyManua.ls Logo

Ingersoll-Rand UP5 11c - User Manual

Ingersoll-Rand UP5 11c
80 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
80447113
Revision A
July 2013
Save These Instructions
Contact-Cooled Rotary Screw Air Compressor
Installation, Operation and Maintenance
UP5 4, UP5 5, UP5 7, UP5 11c
UP6 5, UP6 7, UP6 10, UP6 15c
Installation, exploitation et maintenance
FR
Instalação, operação e manutenção
PT
Installation, Operation and Maintenance
EN
Instalación, operación y mantenimiento
ES
71113.13.16

Table of Contents

Questions and Answers

  • K
    Kristina ObrienAug 7, 2025
    Why drain timer will not operate on my Ingersoll-Rand UP5 11c Air Compressor?
    • C
      Chelsea JonesAug 8, 2025
      If the drain timer on your Ingersoll-Rand Air Compressor isn't working, first ensure it's receiving electrical power. If power is supplied, the timer itself may be malfunctioning and need replacement. A clogged port or strainer could also be the cause, so clean the valve and strainer. Additionally, a malfunctioning solenoid valve can prevent the timer from operating, so consider replacing the solenoid valve.
  • M
    Maurice RichardsAug 23, 2025
    What to do if the solenoid condensate valve will not close on my Ingersoll-Rand Air Compressor?
    • N
      natalie88Aug 23, 2025
      If the solenoid condensate valve on your Ingersoll-Rand Air Compressor won't close, it might be due to debris preventing the diaphragm from seating properly. Try removing the solenoid valve, disassembling it, cleaning all the parts, and then reassembling it. Also, a short in the electrical components could be the culprit. Inspect the power cord or timer and replace them if necessary.

Summary

Foreword

Safety

Installation and Handling

Location in the Plant

Guidance on selecting the optimal location for compressor installation.

Discharge Piping Requirements

Specifications and recommendations for compressor discharge piping.

Electrical Data and Connections

Information on electrical data, isolators, wiring, and voltage compatibility.

Operating Instructions

General Operation Overview

Basic operational principles and environmental operating ranges for the compressor.

Compressor Control Functions

Details on the compressor's control system, including start/stop and pressure settings.

Operating Modes and Selection

Explanation of automatic start & stop and dual control modes for operation.

Starting and Stopping Procedures

Steps for preparing, starting, and safely stopping the compressor.

Maintenance

Maintenance Schedule

Schedule outlining periodic maintenance tasks and recommended intervals for the compressor.

Routine Maintenance Overview

General guidelines and overview of routine maintenance activities.

Coolant System Maintenance

Procedures for topping up, changing coolant, and replacing the coolant filter.

Component Maintenance Procedures

Steps for replacing air filters, separator elements, cleaning coolers, and adjusting belts.

Electric Drain Valve Maintenance

Maintenance and troubleshooting for the electric drain valve system.

Separators and Filters Maintenance

Procedures for moisture separator and air filter maintenance.

Unit Disassembly and Refrigeration

Guidelines for unit disassembly, refrigerant leaks, charging, and R134A characteristics.

Trouble Shooting

Ingersoll-Rand UP5 11c Specifications

General IconGeneral
ModelUP5 11c
Power11 kW
Horsepower15 HP
Pressure125 psi
Weight350 kg
TypeRotary Screw
Air Delivery1.46 m³/min
Phase3

Related product manuals