6 IDS400 INSTALLER MANUAL NO. 700-204-02A ISSUED NOV 2000 VER 1.01
IDS400 INSTALLER MANUAL
1. Introduction to the IDS400
The IDS400 is a versatile, state of the art, microprocessor based, four
zone alarm panel. Most features are optional and may be programmed
either directly through the keypad or via the telephone system, using
the IDS download software and appropriate modem. There are four
programmable burglary zones, appropriate siren and auxiliary power
outputs and 2 outputs which may be programmed to perform various
trigger/switching functions.
For correct operation the IDS400 must be used in conjunction with the
specified transformer/battery combination and appropriate peripheral
sensors and signalling devices.
1.1 Features
v Four wire keypad operation - up to a maximum of 3 keypads.
v Four, fully programmable, end-of-line supervised zones, and 1
dedicated panic zone per keypad which is not end-of-line
supervised.
v Fully programmable digital telephone communicator which
supports most industry standard formats.
v Two programmable trigger outputs.
v Non volatile EEPROM memory retains all program and event log
data in the event of a total power failure.
v Programmable loop response time for all zones (global).
v Up and downloadable using IDS windows based software.
v Excellent protection against lightning (provided by specialised
“zap tracking” and transient suppressors).
v Event log date and time stamped.
v Fax defeat allows download access to the panel with other
devices connected to the phone line.
v Programmable silent or audible panic.