5 Troubleshooting
- 36 -
Error Code Content
6336+10*X Data error, standard error frame
6337+10*X Reserved
6338+10*X Frame error, standard error frame
6339+10*X
Serial protocol error, not conguring corresponding
protocol when using Modbus or RS instruction
6380– 6399: CAN communication error code
6380 Transmitting timeout
6381 Receiving timeout
6382 CAN transmitting busy
6383 CAN receiving busy
6384-6399 Reserved
16300-16319 Ethernet communication error code
16300-16311 Reserved
16312 Protocol designator error Modbus protocol
16313 Frame length error
16314 Frame timeout error
16315 Frame not recognized by slave (only for master)
16316 IP address illegal
16317-16319 Reserved
16320-16339 Extension module communication error code
16340-16359 USB communication error code
16360-16379 Control panel and interface communication error code
16380-16399 Reserved
26300-26399 Reserved