MD380 User Manual Preface
- 1 -
Preface
Thank you for purchasing the MD380 series AC drive developed by Inovance.
The MD380 series AC drive is a general-purpose high-performance current vector control AC
drive and is mainly used to control and regulate the speed of three-phase AC asynchronous
motor. It adopts advanced vector control technology and has low-speed high-torque output,
good dynamc feature and strong overload capacity. It increases the user programmable
function, background monitoring software and communication bus function, and supports
multi-kind PG cards. It is used to drive various automation production equipment involving
textile, paper-making, wiredrawing, machine tool, packing, food, fan and pump.
This manual describes the correct use of the MD380 series AC drive, including selection,
parameter setting, commissioning, maintenance & inspection. Before using the AC drive,
read this manual carefully to have a thorough understanding of the product. Keep the
manual well and forward it with the product to end users.
Notes
The drawings in the manual are sometimes shown without covers or protective guards.
5HPHPEHUWRLQVWDOOWKHFRYHUVRUSURWHFWLYHJXDUGVDVVSHFL¿HG¿UVWDQGWKHQSHUIRUP
operations in accordance with the instructions.
The drawings in the manual are shown for description only and may not match the product
you purchased.
7KHLQVWUXFWLRQVDUHVXEMHFWWRFKDQJHZLWKRXWQRWLFHGXHWRSURGXFWXSJUDGHVSHFL¿FDWLRQ
PRGL¿FDWLRQDVZHOODVHIIRUWVWRLQFUHDVHWKHDFFXUDF\DQGFRQYHQLHQFHRIWKHPDQXDO
Contact our agents or customer service center if you have any problem during the use.
efesotomasyon.com

Table of Contents

Questions and Answers

  • G
    Gina SalazarSep 14, 2025
    What does user-defined fault 2 mean for Inovance MD380S0.4GB?
    • E
      Emily ChristianSep 14, 2025
      If your Inovance DC Drive reports a 'User-defined fault 2', it means the user-defined fault 2 signal is being input via DI or virtual I/O. To resolve this, reset the operation.
  • T
    Teresa JacksonAug 25, 2025
    Why does Inovance MD380S0.4GB DC Drives have overcurrent during acceleration?
    • D
      Daniel WilliamsAug 25, 2025
      When an Inovance DC drive experiences overcurrent during acceleration, it may be due to a grounded or short-circuited output circuit, failure to perform motor auto-tuning, an excessively short acceleration time, an inappropriate manual torque boost or V/F curve, low voltage, starting a rotating motor, a sudden load during acceleration, or an undersized AC drive. To address this, eliminate external faults, perform motor auto-tuning, increase the acceleration time, adjust the manual torque boost or V/F curve, correct the voltage, use rotational speed tracking restart or wait for the motor to stop before starting, remove the added load, or select an AC drive with a higher power class.
  • K
    Kathryn MillerAug 25, 2025
    What to do if Inovance MD380S0.4GB show overcurrent at constant speed?
    • D
      Destiny JonesAug 26, 2025
      If you observe overcurrent at constant speed in Inovance DC Drives, it could be caused by a grounded or short-circuited output circuit, failure to perform motor auto-tuning, low voltage, a sudden load during operation, or an AC drive model with insufficient power. To fix this, eliminate any external faults, perform motor auto-tuning, ensure the voltage is within the normal range, remove any added loads, or choose an AC drive with a higher power class.
  • N
    nsmithAug 26, 2025
    Why does Inovance DC Drives have overvoltage during deceleration?
    • J
      Jessica HayesAug 26, 2025
      If overvoltage occurs during deceleration in Inovance DC Drives, it could be due to high input voltage, an external force driving the motor, a deceleration time that is too short, or the absence of a braking unit and resistor. To solve this, adjust the voltage to the normal range, eliminate the external force or install a braking resistor, increase the deceleration time, or install the braking unit and braking resistor.
  • D
    david95Sep 14, 2025
    What does accumulative power-on time reached mean for Inovance MD380S0.4GB?
    • W
      William LeonardSep 15, 2025
      If your Inovance DC Drive indicates that the 'Accumulative power-on time reached', it signifies that the preset power-on time has been reached. Clear the record by using the parameter initialization function.
  • M
    matthewjacksonSep 23, 2025
    What causes initial position fault in Inovance DC Drives?
    • C
      Carolyn RomeroSep 23, 2025
      If your Inovance DC Drive shows an initial position fault, it means the motor parameters are not set based on the actual situation. Check that the motor parameters are set correctly and verify that the setting of rated current is not too small.
  • R
    roychristineSep 7, 2025
    What does AC drive hardware fault mean in Inovance DC Drives?
    • J
      Jane RosalesSep 7, 2025
      If your Inovance DC Drive displays an 'AC drive hardware fault', it indicates either an overvoltage or overcurrent condition. Address the issue based on the specific overvoltage or overcurrent troubleshooting steps.
  • D
    Douglas CarterSep 8, 2025
    What causes pulse-by-pulse current limit fault in Inovance MD380S0.4GB?
    • E
      Elizabeth MoranSep 8, 2025
      If your Inovance DC Drive is experiencing a pulse-by-pulse current limit fault, it could be due to an excessively heavy load, a locked rotor on the motor, or an AC drive model with insufficient power. To fix this, reduce the load and check the motor and mechanical condition, or select an AC drive of higher power class.
  • D
    Daniel Ramos DDSSep 23, 2025
    What causes EEPROM read- write fault in Inovance MD380S0.4GB?
    • M
      Mark CooperSep 23, 2025
      If your Inovance DC Drive displays an EEPROM read-write fault, it indicates that the EEPROM chip is damaged. Replace the main control board to resolve this.
  • S
    Stephanie ScottAug 31, 2025
    What causes power input phase loss in Inovance MD380S0.4GB?
    • C
      Carolyn ChandlerAug 31, 2025
      If your Inovance DC Drives show power input phase loss, it could be due to an abnormal three-phase power input, a faulty drive board, a faulty lightening board, or a faulty main control board. To address this, eliminate external faults or contact Inovance or their agent.

Summary

Chapter 1 Safety Information and Precautions

1.1 Safety Information

Detailed safety precautions for installation, wiring, operation, and maintenance.

1.2 General Precautions

General safety guidelines including RCD requirements, motor insulation, and thermal protection.

Chapter 3 Mechanical and Electrical Installation

3.1 Mechanical Installation

Guidelines for installing the MD380 AC drive, including environmental and clearance requirements.

3.2 Electrical Installation

Instructions for electrical installation, covering main and control circuit terminals and wiring.

Chapter 4 Operation, Display and Application Examples

4.1 Operation Panel

Detailed description of the MD380 operation panel, including indicators, keys, and digital display.

4.2 Viewing and Modifying Function Codes

Procedure for navigating and modifying function codes using the three-level menu structure.

4.7 Starting or Stopping the AC Drive

Methods for starting and stopping the AC drive, including command source selection.

4.8 Setting the Frequency Reference

Configuration of main and auxiliary frequency sources, including digital, analog, and communication inputs.

4.9 Setting and Auto-tuning of Motor Parameters

Procedures for setting motor parameters and performing auto-tuning for optimal performance.

Chapter 6 Description of Function Codes

Chapter 7 EMC

7.3 Selection of Peripheral EMC Devices

Recommendations for selecting peripheral EMC devices like input filters and reactors for optimal performance.

7.5 Solutions to Current Leakage

Methods to address current leakage issues, including circuit breaker selection and carrier frequency reduction.

7.6 Solutions to Common EMC Interference Problems

Practical solutions for common EMC interference types like leakage, AC drive, communication, and I/O interference.

Chapter 8 Selection and Dimensions

8.1 Electrical Specifications of the MD380

Table of electrical specifications for MD380 models, including power capacity, current ratings, and adaptable motor data.

8.2 Physical Appearance and Mounting Dimensions of the MD380

Detailed physical appearance and mounting dimensions for MD380 AC drives in various housing types.

Chapter 9 Maintenance and Troubleshooting

9.1 Routine Repair and Maintenance of the MD380

Procedures for routine maintenance and periodic inspection of the MD380 AC drive to ensure optimal performance and longevity.

9.3 Faults and Solutions

Comprehensive guide to identifying and resolving common faults and errors encountered with the MD380 AC drive.

9.4 Common Symptoms and Diagnostics

Troubleshooting common operational symptoms and diagnostic procedures for the MD380 AC drive.

Inovance MD380S0.4GB Specifications

General IconGeneral
BrandInovance
ModelMD380S0.4GB
CategoryDC Drives
LanguageEnglish