EasyManua.ls Logo

Inovance MD380L User Manual

Inovance MD380L
42 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
MD380L Open Loop Elevator Drive Quick Start Manual
MD380L
Open Loop Elevator Drive
Quick Start Manual
V0.5
Data Code:19010299
Inova Automation Co., Limited
Address:Unit B01, 17/FMG Tower, 133 Hoi Bun Road, Kwun Tong, Hong Kong
Tel: (852) 2751 6080
Fax: (852) 2751 6933
Email: info@inova-automation.com
Http://www.inovance.cn
Question and Answer IconNeed help?

Do you have a question about the Inovance MD380L and is the answer not in the manual?

Inovance MD380L Specifications

General IconGeneral
BrandInovance
ModelMD380L
CategoryDC Drives
LanguageEnglish

Summary

Product Information

Nameplate Details

Details found on the product's nameplate.

Model Designation Rule

Explains the coding system for product models.

General Specifications

Lists the technical specifications of the drive.

Wiring

Typical Wiring 1

Illustrates typical wiring for multi-reference frequency input.

Typical Wiring 2

Illustrates typical wiring for analog frequency input.

Main Circuit Terminal Description

Describes terminals for the main power and motor connections.

Control Board Terminal Description

Details terminals on the main control board.

Extension I/O Card MD38101 Details

Explains the function, terminals, and configuration of the MD38101 expansion card.

Operation Panel

Operation Panel Overview

Describes the layout, indicators, and display of the operation panel.

Keypad Functions and Parameters

Details the functions of each key and related operational parameters.

Parameter Navigation and Groups

Shows how to navigate parameters and lists parameter group arrangements.

Quick Setup

Normal Travel Timing Diagram

Visualizes the sequence of operations for normal elevator travel.

Elevator Performance Fine-Tuning

Provides guidance on adjusting parameters for optimal elevator performance.

Setup Flowchart

Step-by-step guide for initial setup and parameter configuration.

IGBT Enable Function

Explains the function and application of IGBT Enable for safety.

Function Code Table

Fundamental Parameters (Group F0)

Lists core configuration settings for the drive.

Motor Parameters (Group F1)

Defines parameters related to motor characteristics and setup.

Vector Control Parameters (Group F2)

Details parameters for vector control operation.

VF Control Parameters (Group F3)

Lists parameters specific to the Voltage/Frequency control mode.

Input Terminal Functions (Group F4)

Assigns functions to digital and analog input terminals.

Output Terminal Functions (Group F5)

Configures output terminals for various signals and functions.

Start and Stop Control (Group F6)

Parameters for controlling motor start, stop, and acceleration/deceleration.

Version Checking Parameters (Group F7)

Functions for checking product and software versions.

Auxiliary Functions (Group F8)

Parameters for additional system functions and adjustments.

Fault and Protection Parameters (Group F9)

Settings for fault detection, protection, and error handling.

Multi-Reference Settings (Group FC)

Configuration for multiple reference sources.

Drive Parameters (Group FF)

General drive configuration parameters.

Function Code Management (Group FP)

Settings for managing parameter display and initialization.

Control Optimization (Group A5)

Parameters for optimizing drive performance.

Monitoring Parameters (Group U0)

Parameters for real-time monitoring of drive status.

Troubleshooting Guide

Inverter Fault Codes

Lists error codes, their causes, and recommended solutions.

Common Symptoms and Diagnostics

Addresses common operational issues and their troubleshooting steps.