5.7 Group F6: start and stop control
Function
Code
Parameter name Setting Range
Unit
Default
Commission
F6-00 Start mode 0 : Direct start
1 : Rotational speed tracking restart
2 : Pre-excited start (asynchronous motor)
N.A
0
F6-03 Startup frequency 0.0 to 10.0
Hz
1.0
F6-04 Startup frequency
active set
time
0.0 to 100.0
Sec
0.3
F6-05 DC injection 1 level 0 to 150 %
0
F6-06 DC
injection 1 active set time
0.0 to 5.0
Sec
0
F6-07 Acceleration/Deceleration
mode
0 : Linear acceleration/ deceleration
3: S-curve acceleration/ deceleration C
N.A
3
F6-08 Time proportion of S-curve
Accel start
0.0% to Min[(100.0% - F6-09), 80%]
%
80.0
F6-09 Time proportion of S-curve
Accel end
0.0% to Min[(100.0% - F6-08), 80%]
%
10.0
F6-10 Stop mode 0 : Decelerate to stop
1 : Coast to stop
N.A
0
F6-11 DC injection 2 frequency
threshold
0.00 Hz to maximum frequency
Hz
0.50
F6-12 DC Injection 2 delay ON
set
time
0.0 to 36.0
Sec
0.0
F6-13 DC injection 2 level 0 to 150 %
30
F6-14 DC
injection 2 active set time
0.0 to 5.0
Sec
0.5
F6-26 Time proportion of S-curve
Decel start
0.0% to Min[(100.0% - F6-27), 80%]
%
20.0
F6-27 Time proportion of S-curve
Decel end
0.0% to Min[(100.0% - F6-26), 80%]
%
30.0
5.8 Group F7: product and software version checking
Function
Code
Parameter name Setting Range
Unit
Default
Commission
F7-08 Product number N.A.
N.A.
380.00
display
F7-10 Performance software
version
N.A.
N.A.
312.xx display
F7-11 Functional software version
N.A.
N.A.
312.xx
display
F7-15 Performance software
temporary version
N.A.
N.A.
0.00 display
F7-16 Functional software
temporary version
N.A.
N.A.
0.00 display