EasyManua.ls Logo

Inovance MD380L - Function Code Table; Fundamental Parameters (Group F0)

Inovance MD380L
42 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
23
5 Function code table
NOTE: not all parameters are listed, here below are relevant to open loop elevator applications.
5.1 Group F0: fundamental
Function
Code
Parameter name Setting Range
Unit
Default
Commission
F0-01 Motor 1 control mode 0 : Sensor-less flux vector control (SFVC)
2 : V/F control
N.A
2
F0-02 Command source selection 0 : Operation panel control (LED off)
1 : Terminal control (LED on)
2 : Communication control (LED flashing)
N.A
1
F0-03 Main frequency source X
selection
2 : AI-1
3 : AI-2
4 : AI-3
6 : Multi-reference
N.A
6
F0-07 Frequency source selection 0 : Main frequency source X
N.A
0
F0-09 Rotation direction 0: Same direction
1: Reverse direction
N.A
0
F0-10 Maximum frequency 50.00 to 100.00
Hz
50.00
F0-15 Carrier frequency 0.5 to 11.0
(SVC mode: 0.5 to 9)
(VF mode: 0.5 to 11)
kHz
Model
dependant
F0-17 Acceleration time 1 0.00 to 650.00 (F0-19 = 2)
0.0 to 6500.0 (F0-19 = 1)
0 to 65000 (F0-19 = 0)
Sec
3.0
F0-18 Deceleration time 1 0.00 to 650.00 (F0-19 = 2)
0.0 to 6500.0 (F0-19 = 1)
0 to 65000 (F0-19 = 0)
Sec
2.0
F0-19
Acceleration/Deceleration time
unit
0 : 1
1 : 0.1
2 : 0.01
Sec
1 1

Related product manuals