25
5.3 Group F2: vector control
Function
Code
Parameter name Setting Range
Unit
Default
Commission
F2-00 Speed loop proportional
gain 1
0 to 100
N.A
10
F2-01 Speed loop integral time 1 0.01 to 10.00
Sec
0.50
F2-02 Switchover frequency 1 0.00 to F2-05
Hz
3.00
F2-03 Speed loop proportional
gain 2
0 to 100
N.A
30
F2-04 Speed loop integral time 2 0.01 to 10.00
Sec
0.5
F2-05 Switchover frequency 2 F2-02 to maximum output frequency
Hz
7.00
F2-06 SVC slip gain 50 to 200 %
100
F2-10
Torque upper limit (for SVC)
0.0 to 200.0 (% inverter rated current) %
150.0
F2-13 Excitation adjustment
proportional gain
0 to 20000
N.A
2000
F2-14
Excitation adjustment integral
gain
0 to 20000
N.A
1300
F2-15 Torque adjustment
proportional gain
0 to 20000
N.A
2000
F2-16 Torque adjustment integral
gain
0 to 20000
N.A
1300

Related product manuals