31
5.9 Group F8: auxiliary functions
Function
Code
Parameter Name Setting Range
Commission
F8-04 Deceleration time 2 0.0 to 6500.0
Frequency switchover point
and deceleration time 2
0.00 to maximum frequency
Hz
0.00
F8-55 Brake release current
threshold
0 to 200
%
5
F8-56 Brake release frequency
threshold
0.00 to 25.00
Hz
Brake release delay ON set
0.0
F8-58 Brake apply frequency
threshold
0.00 to 25.00
Hz
0.50
F8-59 Brake apply delay OFF set
time
0.0 to 5.0
Sec
0.2
F8-60 Drive run delay ON set time
F8-61 MC contactor delay OFF
set time
0.00 to 10.00
Sec
0.20
5.10 Group F9: fault and protection
Function
Code
Parameter Name Setting Range
Commission
F9-00 Motor thermal protection
enable selection
0: disable motor thermal protection;
1: enable motor thermal protection
N.A
1
F9-01 Motor thermal protection
coefficient
0.1 to 10.00
N.A
Motor thermal protection pre
warning coefficient
50 to 99
% 80
F9-07
Ground fault detection Enable
0: Disable;
1: Enable detection upon power on;
2: Enable detection upon power on and upon
Braking operation voltage level
F9-09 Fault auto reset times
0 to 20
0
F9-11 Time interval of fault auto
reset
0.1 to100.0
Sec
1.0
F9-13 Drive output phase loss
detection Enable
0: Disable;
1: Enable detection during running;
2: Enable detection upon start and during
running
N.A
3rd (latest) fault type 0 to 51
Frequency upon 3rd fault N.A.
Current upon 3rd fault N.A.
A
Bus voltage upon 3rd fault N.A.
V