MD380 User Manual Desc
ription of Function Codes
- 243 -
*URXS80RQLWRULQJ3DUDPHWHUV
*URXS8LVXVHGWRPRQLWRUWKH$&GULYHVUXQQLQJVWDWH<RXFDQYLHZWKHSDUDPHWHU
values by using operation panel, convenient for on-site commissioning, or from the host
computer by means of communication (address: 0x7000-0x7044).
8WR8DUHWKHPRQLWRULQJSDUDPHWHUVLQWKHUXQQLQJDQGVWRSVWDWHGH¿QHGE\)
03 and F7-04. For more details, see Table 6-1.
Function Code Parameter Name Display Range
8 Running frequency 0.00–500.00 Hz
8 Frequency reference 0.00–500.00 Hz
These two parameters display the absolute value of theoretical running frequency and
IUHTXHQF\UHIHUHQFH)RUWKHDFWXDORXWSXWIUHTXHQF\RIWKH$&GULYHVHH8
Function Code Parameter Name Display Range
8 Bus voltage 0.0–3000.0 V
It displays the AC drive's bus voltage.
Function Code Parameter Name Display Range
8 2XWSXWYROWDJH 0–1140 V
It displays the AC drive's output voltage in the running state.
Function Code Parameter Name Display Range
8 2XWSXWFXUUHQW
±$$&GULYHSRZHUN:
±$$&GULYHSRZHU!N:
It displays the AC drive's output current in the running state.
Function Code Name Display Range
8 2XWSXWSRZHU 0–32767
It displays the AC drive's output power in the running state.
Function Code Parameter Name Display Range
8 2XWSXWWRUTXH -200.0%–200.0%
It displays the AC drive's output torque in the running state.
Function Code Parameter Name Display Range
8 DI state 0–32767
It displays the current state of DI terminals. After the value is converted into a binary number,
each bit corresponds to a DI. "1" indicates high level signal, and "0" indicates low level signal.
The corresponding relationship between bits and DIs is described in the following table.