Chapter 4 Operation and Trial Running
- 26 -
Figure 4-3 Example of editing function code
F015.00
PRG
F000
00.00
PRG
PRG
ENTER
ENTER
ENTER
PRG
F005
15.00
F004
Status parameter
(default display)
To save the
setting
If there is a blinking digit,
press / / to modify the digit.
In Level III menu, if the parameter has no blinking digit, it means that the parameter cannot be
modied. This may be because:
Such a function code is only readable, such as actually detected parameter and running
record parameter.
Such a function code cannot be modied in the running state and can only be changed at
stop.
4.2.2 Viewing Fault Information
When a fault occurs on the controller, the operation panel displays the fault code, based on
which, you can nd the cause of the fault and rectify the fault quickly.
The controller saves the last four fault codes, and details of the frequency, current, bus voltage
and DI/DO status at the latest fault are recorded.
Figure 4-4 Viewing fault information
F0
15.00
PRG
FA00
00.00
PRG
PRG
ENTER
ENTER
ENTER
PRG
FA03
FA02
FA
Status parameter
(default display)
If there is a blinking digit,
press / / to modify the digit.