DIAGNOSTIC CODES FOR CBD6S
CODES NAME DESCRIPTION POTENTIAL CAUSE SOLUTION/TROUBLESHOOTING
E88 Slave 2
Connection to
2nd slave lost OR
following messages
are from 2nd slave
• [Only used in multiparallel
system]
• Poor cable connection
to slave box
• If followed by another error
code, then codes being
communicated from slave box
• Check connection to master
box, check cable integrity
• If communicating other
error codes, see above
E89 Slave 3
Connection to
3rd slave lost OR
following messages
are from 3rd slave
• Damage to motor cable
• Damage to cable exiting
leg (if applicable)
• Inspect motor cable for
damage, replace if damaged
• Inspect cable exiting leg (if
applicable), replace if damaged.
100
Forced
initialization
Reference 1
Forced initialization was
initiated on this reference.
Note: This code is
not transmitted in
LINBUS, therefore it is
not displayed on the
desk panel. It is only
viewable in the CBD6S
congurator list of most
recent 10 error codes.
- -
101
Forced
initialization
Reference 2
- -
102
Forced
initialization
Reference 3
- -
103
Forced
initialization
Reference 4
- -
Error Codes
Height Adjustable Table – User Guide | October 2019 19