Configuring the Fuel System Type:
Line 6 of the Engine Configuration screen is the Fuel parameter that defines the fuel system configuration.
There are three choices INJECTED, CARB or PCARB. The bottom knob is turned to make a selection on this line.
For example to set the G2-3-4 up for a pressurized carburetor with a separate return line perform the following procedure:
When on line 6 turn the
SEL knob clockwise or counter clockwise to select PCARB. The current selection is shown in red.
Use the SEL pushbutton to select Line 9. On line 9 turn the SEL knob clockwise or counter clockwise to set the Save Config
parameter to select YES.
Press the SEL button to save your changes into permanent memory.