6.0 - IN DAILY USE:
Switch boiler on.
Wait for the GREEN LIGHT. The water will then be at the correct temperature.
Dispense water via the lever tap(s) on the front of the boiler (CAUTION: Take care as
boiler dispenses near-boiling water).
7.0 - CLEANING
Clean the external surfaces of the boiler with a damp cloth to maintain hygiene. Do not use
abrasive material on the outer surface of the machine. Wipe the draw-off tap daily to remove
any lime-scale deposits and check that the outlet is clear.
TO CLEAN THE PROBES:
- Disconnect machine from the power supply.
- Lift off outer-lid. After removing the lid the tank is accessible.
- Remove the tank lid by taking out the fixing screws.
- Lift out the baffle plates on the inside of the tank (note the position of these plates so that you
can replace them correctly).
- Wipe clean the level sensing probes using a non-metallic scourer. It is important to ensure that
you also clean the white insulators.
- Reassemble and switch the boiler back on.
8.0 - MAINTENANCE
The boiler should be periodically checked for scale build-up. The frequency depends upon
hardness of the water and whether or not an effective scale reducer is fitted.
Draw-Off Tap: The draw-off tap components are subject to wear & tear. We strongly
recommend that the tap is inspected periodically (at least once a year as part of a general
maintenance routine). It is advisable to keep a spare tap spring and washer in case of
emergencies.
Spare parts and accessories are available from Instanta Limited – Tel: 01704 502905
DE-SCALING:
- Disconnect machine from the power supply,
- Empty the machine through the draw off tap and allow too cool down.
- Lift off the outer-lid. After removing the lid the tank is accessible.
- Remove the tank lid by taking out the four fixing screws.
- Lift out the baffle plates on the inside of the tank.
- Remove as much scale as possible by hand. Any scale which is difficult to remove can be
dissolved by using a solution of de-scaler.
- Wipe clean the level sensing probes.
- Ensure all traces of de-scaler are removed before using the boiler again.
9.0 - SERVICE WARNINGS AND FAULT DIAGNOSIS
Your boiler is fitted with an intelligent fault diagnosing system and is able to detect the fault
conditions below:
1 Flashing Green - The bottom probe is scaled up
2 Flashing Orange - The water supply is off
3 Flashing Red - An internal component has failed. Contact Instanta
Service Department – 01704 502911
4 Flashing Red & Green - As 3 above