Service/Technical Support
Tel: 01704 502911
To ensure your service enquiry is handled as
efciently as possible, please have the following
information available:
• Brief description of problem.
• Product Type (model).
• Serial Number (label on under-side of
boiler-case). This is essential.
Guarantee
Your boiler is guaranteed for 2 years from date
of installation.
Our guarantee includes on-site labour and parts
for problems caused by fault of manufacture and
component failure with the following exclusions:
• Problems caused by hard water and lime
scale. We regret we cannot be held
responsible for problems caused by hard
water.
• Dripping Taps. These components are
subject to wear & tear but in the event of a
tap failing, within 12 months of installation,
we will be pleased to replace the tap
assembly by post. Fitting is very simple
and requires no tools. An engineer call out
is not necessary.
• Accidental damage, misuse or use not in
accordance with these instructions and
damage caused by incorrect installation.
The manufacturer disclaims any liability for
incidental, or consequential damages.
Full Program Menu
1 SET CLOCK TIME (24h)
SET CLOCK – HOURS
SET CLOCK – MINUTES
SET CLOCK – MONDAY
SET CLOCK – TUESDAY
SET CLOCK – WEDNESDAY
SET CLOCK – THURSDAY
SET CLOCK – FRIDAY
SET CLOCK – SATURDAY
SET CLOCK – SUNDAY
1a RESET THE FILTER
[resets lter-monitor when a new cartridge
is installed]
NOTE: This menu option only appears in
the menu once the lter counter has been
activated
2 TIMER CONTROLLED
SET PERIOD – MONDAY
SET PERIOD – TUESDAY
SET PERIOD – WEDNESDAY
SET PERIOD – THURSDAY
SET PERIOD – FRIDAY
SET PERIOD – SATURDAY
SET PERIOD – SUNDAY
3 SET WATER TEMPERATURE
[Adjustable: 80
o
& 99
o
C - Your boiler
has been factory-set. We do not recommend
increasing the factory-set temperature]
4 SET FILTER CAPACITY
[Enable lter monitor and set number of
litres]
5 SET HEATER RATING
[Select KW rating of boiler: 1.5KW - 18KW
KW]
6 ECO MODE BUTTON
[Enable or disable. Disable if you do not
want to use Eco Mode]
7 OVERRIDE BUTTON
[Enable or Disable…you can override the
timer settings by pressing the ON/OFF
button at any time. If you do not want to
allow this to happen, disable the override
button]
8 PROGRAM MODE EXIT
[Exit program menus]
9 TEST PROBES
[Shows which sensors in contact with water]
10 DISPLAY ADC VALUES
[Manufacturers test values)
11 VOLTAGE & LOAD TEST
[Takes a reading of mains supply voltage]
12 POWER UP MODE
[Last-used, always-off, always on]
13 SHOW CLOCK ON DISPLAY
[Enable or disable clock/time display]
14 LOAD DEFAULTS
[Returns boiler to factory-set defaults]
15 ENG MODE 1 STATUS
[Not used]
16 ENG MODE 2 STATUS
[Not used]
17 PROGRAM MODE EXIT
[Exit program menus]
10 11