8XC196KC/8XC196KC20
EPROM SPECIFICATIONS
OPERATING CONDITIONS DURING PROGRAMMING
Symbol Description Min Max Units
T
A
Ambient Temperature During Programming 20 30 C
V
CC
Supply Voltage During Programming 4.5 5.5 V
(1)
V
REF
Reference Supply Voltage During Programming 4.5 5.5 V
(1)
V
PP
Programming Voltage 12.25 12.75 V
(2)
V
EA
EA Pin Voltage 12.25 12.75 V
(2)
F
OSC
Oscillator Frequency During Auto and Slave 6.0 8.0 MHz
Mode Programming
F
OSC
Oscillator Frequency During 6.0 16.0 MHz
Run-Time Programming (8XC196KC)
F
OSC
Oscillator Frequency During 6.0 20.0 MHz
Run-Time Programming (8XC196KC20)
NOTES:
1. V
CC
and V
REF
should nominally be at the same voltage during programming.
2. V
PP
and V
EA
must never exceed the maximum specification, or the device may be damaged.
3. V
SS
and ANGND should nominally be at the same potential (0V).
4. Load capacitance during Auto and Slave Mode programming
e
150 pF.
AC EPROM PROGRAMMING CHARACTERISTICS
Symbol Description Min Max Units
T
SHLL
Reset High to First PALE Low 1100 T
OSC
T
LLLH
PALE Pulse Width 50 T
OSC
T
AVLL
Address Setup Time 0 T
OSC
T
LLAX
Address Hold Time 100 T
OSC
T
PLDV
PROG Low to Word Dump Valid 50 T
OSC
T
PHDX
Word Dump Data Hold 50 T
OSC
T
DVPL
Data Setup Time 0 T
OSC
T
PLDX
Data Hold Time 400 T
OSC
T
PLPH
(1)
PROG Pulse Width 50 T
OSC
T
PHLL
PROG
High to Next PALE Low 220 T
OSC
T
LHPL
PALE High to PROG Low 220 T
OSC
T
PHPL
PROG High to Next PROG Low 220 T
OSC
T
PHIL
PROG High to AINC Low 0 T
OSC
T
ILIH
AINC Pulse Width 240 T
OSC
T
ILVH
PVER Hold after AINC Low 50 T
OSC
T
ILPL
AINC Low to PROG Low 170 T
OSC
T
PHVL
PROG High to PVER Valid 220 T
OSC
NOTE:
1. This specification is for the Word Dump Mode. For programming pulses, use the Modified Quick Pulse Algorithm. See
user’s manual for further information.
21