Technical Reference
65
2.8 Reliability
The Mean Time Between Failures (MTBF) prediction is calculated using component and
subassembly random failure rates. The calculation is based on the Telcordia SR-332,
Issue 2; Method I, Case 3, 55 ºC ambient. The MTBF prediction is used to estimate
repair rates and spare parts requirements. The MTBF for the Intel Desktop Board
DH61AGL is 61,767 hours.
2.9 Environmental
Table 35 lists the environmental specifications for the board.
Table 35. Environmental Specifications
Parameter Specification
Temperature
Non-Operating
-40 °C to +60 °C
Operating
0 °C to +60 °C
Shock
Unpackaged 50 g trapezoidal waveform
Velocity change of 170 inches/s²
Packaged Dimension of package (L x W x H) 465 x 220 x 230 mm
Package weight 12.54 pounds
Drop height 36 inches
Drop sequence (total drops) 6 faces, 2 corners, 3 edges (11)
Vibration
Unpackaged 5 Hz to 20 Hz: 0.01 g² Hz sloping up to 0.02 g² Hz
20 Hz to 500 Hz: 0.02 g² Hz (flat)
Packaged 5 Hz to 40 Hz: 0.015 g² Hz (flat)
40 Hz to 500 Hz: 0.015 g² Hz sloping down to 0.00015 g² Hz