EasyManua.ls Logo

Intellihot i200X - User Manual

Intellihot i200X
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
To avoid product damage, personal injury, or
even possible death, carefully read, understand,
and follow all the instructions in the Installation
and Operation manuals before installing this
product. Improper installation, adjustment, alteration, or
maintenance can cause injury, loss of life, and/or property
damage. This water heater should be installed and
serviced by a qualified technician. The lack of proper
service can result in a dangerous condition.
This manual contains safety information, installation
instructions, and maintenance procedures. It must be left
with the homeowner or placed near the water heater in
a noncombustible place. The customer should retain this
manual for future reference.
WARNING
If the information in these instructions is not followed
exactly, a fire or explosion could result causing
property damage, personal injury, or death.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
If you cannot reach your gas supplier, call the
fire department.
Installation and service must be performed by
a qualified installer, service agency, or the gas
supplier.
FA
CT
OR
Y PRESET FOR USE WITH
NATURAL GAS
Dir
ect-Vent Automatic Instantaneous
Wat
er Hea
te
r
(Chauffe-eau automatique instantané à ventilation directe)
FOR INDOOR INST
ALLA
TION ONLY
(POUR INSTALLATION À L'INTÉRIEUR SEULEMENT)
120 V
olt, 60 Hz, 5
Amps
Ty
pe of Gas
(Type de gaz)
: . . . . . . . . . . . . . . . .
Input Rating
(Entrer le Classement)
: Btu/hr Maximu
m
. . .
Btu/hr Minimum . . .
Maximum Inlet Gas Pressure:
. . . . . . . . . . . .
Minimum Inlet Gas Pressure:
. . . . . . . . . . . .
Minimum Inlet Gas Pressure (for adjustments): . .
Maximum
Wa
ter Pressure:
. . . . . . . . . . . . .
Minimum
Wa
ter Pressure:
. . . . . . . . . . . . .
Recovery Rating: . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . .
Thermal Effi
ciency / :
Energy Factor:
NOx Emissions:
. . . . . . . .
(Pursuant to South Coast Air Quality Management District Rule 1
146.2)
(Moins de 20 ppm)
(Jusqu'à 98 % / 0.94)
(Jusqu'à 98 % / 0.94)
(Moins de 20 ppm)
(Dégagements minimums)
(Des non-combustibles)
(D'une construction
combustible)
(conformément au règlement 1146.2 du "South Coast Air Quality Management District)
Top of heater
Minimum Clearances
From
Non-Combustibles
From Combustible
Construction
(Dessus du chauffe-eau)
Back of heater
(Arrière du chauffe-eau)
Front of heater
(Avantdu chauffe-eau)
Bottom of cabinet
(Côté canalisation)
Side
(Côté)
5/8 in (15.8 mm)
6 in (15.2 cm)
6 in (15.2 cm)
2 in (50.8 mm)
12 in (30.4 cm)
5/8 in (15.8 mm)
6 in (15.2 cm)
2 in (50.8 mm)
1/2 in (12.7 mm)
12 in (30.4 cm)
Intellihot Green Technologies Inc
.
2900 W. Main St.
Galesburg, IL 61401
Phone:
(877) 835- 1705
Email:
info@intellihot.com
We
b:
www
.intellihot.com
F
actor
y Pr
eset
Na
tur
al Gas
(Réglage en usine pour gaz naturel)
199,000
20,000
13.0 W.
C. (3.20 kPa)
8.0
W.
C. (2.00 kPa)
8.0 W.
C. (2.00 kPa)
150 psi (1034 kPa)
15 psi (103 kPa)
265 GPH (1003 LPH)
Up to 98% / 0.94
Less than 20 ppm
Field Co
nv
er
sion* to
Pr
opane Gas
(Conversion* sur place au gaz propane)
199,000
20,00
0
10.5
W.
C. (2.62 kPa)
3.0 W.
C. (0.76 kPa)
11.0
W.
C. (2.74 kPa)
150 psi (1034 kPa)
15 psi (103 kPa)
265 GPH (1003 LPH)
Up to 98% / 0.94
Less than 20 ppm
Check
Box if
Converted to
Propane
Gas
*Refer to Installation and Operation
manual for conversion procedure.
(Se référer au manuel d'installation et
de fonctionnement pour la procédure de
conversion.)
PRÉRÉGLAGES D'USINE POUR UTILISATION AVEC
GAZ NA
TURE
L
(Pression de gaz d'arrivée maximum)
(Pression d'eau maximum)
(Pression d'eau minimum)
(Caractéristique de recouvrement)
(Efficacité thermique / Facteur énergétique)
(Émissions de NOx)
(Pression de gaz d'arrivée minimum)
(Pression de gaz d'arrivée minimum (pour ajustements))
Cocher la case si converti au gaz propane
ETL STICKER
Serial Number:
IGT-LBL-0005-01
(Numéro de série)
(Collant ETL)
Operation
Manual
Model: i200X
i250X
Intellihot Direct Vent Boiler/ Combination Water
heater. This product complies with ANSI Z21.13-
(2010) / CSA 4.9 Low Pressure Boiler and with
ANSIZ21.10.3 (2011) / CSA 4.3 Gas Water Heater. For
use as potable water heating and space heating.
Smart. Ecient. Endless
Ne pas entreposer ni utiliser d’essence ou
ni d’autres vapeurs ou liquides inflammables
à proximité de cet appareil ou de tout autre
appareil.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ
Ne pas tenter d’allumer d’appareil.
Ne touchez à aucun interrupteur; ne pas vous
servir des téléphones se trouvant dans
le bâtiment.
Appelez immédiatement votre fournisseur de gaz
depuis un voisin. Suivez les instructions
du fournisseur.
Si vous ne pouvez rejoindre le fournisseur,
appelez le service des incendies.
L’installation et l’entretien doivent être assurés
par un installateur ou un service d’entretien
qualifié ou par le fournisseur de gaz.
AVERTISSEMENT
Assurez-vous de bien suivre les instructions données
dans cette notice pour réduire au minimum le
risque d’incendie ou d’explosion ou pour éviter tout
dommage matériel, toute blessure ou la mort.
Certified to
NSF/ANSI 372

Other manuals for Intellihot i200X

Questions and Answers

  • J
    Joanna GarciaAug 14, 2025
    Why does my Intellihot i200X Water Heater have ignition failure?
    • T
      trobinsonAug 14, 2025
      If your Intellihot Water Heater fails to ignite, it could be due to several reasons. A possible cause is a tripped water over-heat switch, so check the pump and cross over solenoid. Another potential cause is low gas pressure, in which case you should adjust the gas pressure at the regulator, check or upsize the gas line, and check for any gas line blockages. It could also be a faulty DSI, igniter wire, ignition connection, PCB, or a bad igniter, requiring you to replace the part. If the problem persists, turn the control panel OFF, shut the gas valve, unplug the unit, and contact an authorized service technician.
  • M
    Morgan HendersonAug 17, 2025
    How to fix a blower speed fault on Intellihot i200X Water Heater?
    • D
      Dr. Joseph DeanAug 17, 2025
      If your Intellihot Water Heater is showing a blower speed fault, it could be due to several reasons. The blower might be noisy or the impeller jammed, requiring you to inspect and clean the blower and impeller, removing any obstructions. Another cause could be a disconnected or faulty signal wire or wiring, so check the PWN signal and look for loose wires or pins, and repair them. If the problem persists, turn the control panel OFF, shut the gas valve, unplug the unit, and contact an authorized service technician.
  • S
    Sherri MccoyAug 20, 2025
    What to do if my Intellihot i200X Water Heater shows a blocked flue fault?
    • S
      stephanie94Aug 21, 2025
      If your Intellihot Water Heater is showing a blocked flue fault, it could be due to a blocked exhaust caused by obstructions like birds. Check the exhaust termination and connection at the water heater, and consider installing screens. Another possible cause is backed-up condensate, so check the slope of the drain and look for double loops, air locks, or debris in the loop. Also, check the wiring in case of loose connections.
  • T
    Tanner DunnAug 25, 2025
    Why is the flue temperature exceeding the set limit on my Intellihot i200X?
    • M
      murillobrettAug 25, 2025
      If the flue temperature on your Intellihot Water Heater is exceeding the set limit, it could be due to an incorrect vent setup. If the vent pipe material is CPVC or Polypropylene, ensure that CPVC is selected in the FP (Flue Pipe) mode. High inlet temperature could also be the cause. Ensure the inlet temperature is lower than 150°F if the vent pipe material is PVC or lower than 190°F if the vent pipe material is CPVC or Polypropylene. Check for nicked or broken sensor wiring and connectors. Also check for corroded or wet connectors. You can measure the resistance of the sensor at the connector (18 Kohm at 50°F, 10 Kohm at 77°F, 3 Kohm at 140°F). Alternatively, the controller may need to be replaced.
  • C
    carolynshawAug 27, 2025
    What causes the heat exchanger outlet temperature to exceed the set limit in Intellihot i200X Water Heater?
    • B
      Brian SotoAug 27, 2025
      If the heat exchanger outlet temperature on your Intellihot Water Heater is exceeding the set limit, it could be due to excessive flow rate changes. Ensure the water flow rate does not change faster than 2 GPM every 5 seconds. Also, check for nicked or broken sensor wiring or connectors, and inspect for corroded or wet connectors. You can measure the resistance of the sensor at the connector (18 Kohm at 50°F, 10 Kohm at 77°F, 3 Kohm at 140°F). The controller may also need replacement.
  • A
    Amy HobbsAug 31, 2025
    How to troubleshoot a shorted temperature sensor on an Intellihot i200X?
    • C
      Chad WagnerAug 31, 2025
      If your Intellihot Water Heater indicates a temperature sensor is shorted, it may be due to faulty sensor wiring. Check for nicked or broken sensor wiring or connectors, and also inspect for corroded or wet connectors. Another cause could be a faulty sensor, so measure the resistance of the sensor at the connector (18 Kohm at 50°F, 10 Kohm at 77°F, 3 Kohm at 140°F). Alternatively, the controller itself might be faulty and require replacement.
  • M
    Michael CurrySep 3, 2025
    What to do if Intellihot Water Heater displays a temperature sensor open circuit error?
    • K
      Kyle DavisSep 3, 2025
      If your Intellihot Water Heater shows a temperature sensor open circuit, first check the connectors to ensure they are securely connected. Also, check for nicked or broken sensor wiring or connectors, and inspect for corroded or wet connectors. If the wiring is intact, measure the resistance of the sensor at the connector (18 Kohm at 50°F, 10 Kohm at 77°F, 3 Kohm at 140°F). If the issue persists, the controller may need to be replaced.
  • J
    Jorge HarveySep 7, 2025
    Why is the recirculation icon flashing on my Intellihot i200X Water Heater?
    • C
      Charles WadeSep 7, 2025
      If the recirculation icon is flashing on your Intellihot Water Heater, it could indicate several issues: * The pump may be inoperable, so check the pump wiring harness for loose connectors. * The pump might be faulty and excessively hot, requiring replacement. * The controller could be faulty and need replacement. * For P models, the solenoid valve may be plugged up, requiring cleaning of the lines and replacement of the solenoid. * The solenoid valve itself might be faulty and need replacement. * A jammed check valve could also be the cause; remove the check valve access and ensure the gate is free to move.
  • R
    robertdavisSep 10, 2025
    What does a flashing icon mean on my Intellihot i200X?
    • J
      johnkellySep 10, 2025
      If you see a flashing icon on your Intellihot Water Heater, it indicates an error code and the unit is locked out. Refer to the indicated error code (E1, E2, etc.) for resolution.

Summary

Safety

Safety Signal Words

Explains the meaning of DANGER, WARNING, CAUTION, and NOTICE signal words.

Installation Warnings

Details critical safety precautions for installation and operation.

Operation

Resetting (Clear) Error Codes

Guides users on how to clear error codes from the unit's display.

Setting the Domestic Water Temperature

Details how to adjust the output water temperature for domestic use.

Error Screen

Describes how error codes are displayed and where to find troubleshooting information.

Programming

Diagnostic Code and Error Log Selection

Describes how to access and interpret diagnostic codes and error logs.

Maintenance

Draining the Water Heater

Step-by-step guide on how to safely drain the water heater.

Troubleshooting

Error Code Chart

A detailed chart listing error codes and their potential causes and solutions.

Warranty

General

Overview of product warranty terms and coverage.

Warranty Period

Specifies warranty duration for parts and labor.

Heat Exchanger Coil

Details warranty period for the heat exchanger coil.

Intellihot i200X Specifications

General IconGeneral
Modeli200X
CategoryWater Heater
TypeTankless
Fuel TypeNatural Gas or Propane
Thermal Efficiency96%
Activation Flow Rate0.5 GPM
Minimum Flow Rate0.5 GPM
Water Connection3/4" NPT
Gas Connection3/4" NPT
Vent Size2" or 3"
Voltage120V
Warranty10 years
Flow Rate7.0 GPM
Energy Efficiency0.95
Maximum Input199, 000 BTU/hr

Related product manuals