To avoid product damage, personal injury, or
even possible death, carefully read, understand,
and follow all the instructions in the Installation
and Operation manuals before installing this
product. Improper installation, adjustment, alteration, or
maintenance can cause injury, loss of life, and/or property
damage. This water heater should be installed and
serviced by a qualified technician. The lack of proper
service can result in a dangerous condition.
This manual contains safety information, installation
instructions, and maintenance procedures. It must be left
with the homeowner or placed near the water heater in
a noncombustible place. The customer should retain this
manual for future reference.
WARNING
If the information in these instructions is not followed
exactly, a fire or explosion could result causing
property damage, personal injury, or death.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
If you cannot reach your gas supplier, call the
fire department.
Installation and service must be performed by
a qualified installer, service agency, or the gas
supplier.
FA
CT
OR
Y PRESET FOR USE WITH
NATURAL GAS
Dir
ect-Vent Automatic Instantaneous
Wat
er Hea
te
r
(Chauffe-eau automatique instantané à ventilation directe)
FOR INDOOR INST
ALLA
TION ONLY
(POUR INSTALLATION À L'INTÉRIEUR SEULEMENT)
120 V
olt, 60 Hz, 5
Amps
Ty
pe of Gas
(Type de gaz)
: . . . . . . . . . . . . . . . .
Input Rating
(Entrer le Classement)
: Btu/hr Maximu
m
. . .
Btu/hr Minimum . . .
Maximum Inlet Gas Pressure:
. . . . . . . . . . . .
Minimum Inlet Gas Pressure:
. . . . . . . . . . . .
Minimum Inlet Gas Pressure (for adjustments): . .
Maximum
Wa
ter Pressure:
. . . . . . . . . . . . .
Minimum
Wa
ter Pressure:
. . . . . . . . . . . . .
Recovery Rating: . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . .
Thermal Effi
ciency / :
Energy Factor:
NOx Emissions:
. . . . . . . .
(Pursuant to South Coast Air Quality Management District Rule 1
146.2)
(Moins de 20 ppm)
(Jusqu'à 98 % / 0.94)
(Jusqu'à 98 % / 0.94)
(Moins de 20 ppm)
(Dégagements minimums)
(Des non-combustibles)
(D'une construction
combustible)
(conformément au règlement 1146.2 du "South Coast Air Quality Management District)
Top of heater
Minimum Clearances
From
Non-Combustibles
From Combustible
Construction
(Dessus du chauffe-eau)
Back of heater
(Arrière du chauffe-eau)
Front of heater
(Avantdu chauffe-eau)
Bottom of cabinet
(Côté canalisation)
Side
(Côté)
5/8 in (15.8 mm)
6 in (15.2 cm)
6 in (15.2 cm)
2 in (50.8 mm)
12 in (30.4 cm)
5/8 in (15.8 mm)
6 in (15.2 cm)
2 in (50.8 mm)
1/2 in (12.7 mm)
12 in (30.4 cm)
Intellihot Green Technologies Inc
.
2900 W. Main St.
Galesburg, IL 61401
Phone:
(877) 835- 1705
Email:
info@intellihot.com
We
b:
www
.intellihot.com
F
actor
y Pr
eset
Na
tur
al Gas
(Réglage en usine pour gaz naturel)
199,000
20,000
13.0 W.
C. (3.20 kPa)
8.0
W.
C. (2.00 kPa)
8.0 W.
C. (2.00 kPa)
150 psi (1034 kPa)
15 psi (103 kPa)
265 GPH (1003 LPH)
Up to 98% / 0.94
Less than 20 ppm
Field Co
nv
er
sion* to
Pr
opane Gas
(Conversion* sur place au gaz propane)
199,000
20,00
0
10.5
W.
C. (2.62 kPa)
3.0 W.
C. (0.76 kPa)
11.0
W.
C. (2.74 kPa)
150 psi (1034 kPa)
15 psi (103 kPa)
265 GPH (1003 LPH)
Up to 98% / 0.94
Less than 20 ppm
Check
Box if
Converted to
Propane
Gas
*Refer to Installation and Operation
manual for conversion procedure.
(Se référer au manuel d'installation et
de fonctionnement pour la procédure de
conversion.)
PRÉRÉGLAGES D'USINE POUR UTILISATION AVEC
GAZ NA
TURE
L
(Pression de gaz d'arrivée maximum)
(Pression d'eau maximum)
(Pression d'eau minimum)
(Caractéristique de recouvrement)
(Efficacité thermique / Facteur énergétique)
(Émissions de NOx)
(Pression de gaz d'arrivée minimum)
(Pression de gaz d'arrivée minimum (pour ajustements))
Cocher la case si converti au gaz propane
ETL STICKER
Serial Number:
IGT-LBL-0005-01
(Numéro de série)
(Collant ETL)
Operation
Manual
Model: i200X
i250X
Intellihot Direct Vent Boiler/ Combination Water
heater. This product complies with ANSI Z21.13-
(2010) / CSA 4.9 Low Pressure Boiler and with
ANSIZ21.10.3 (2011) / CSA 4.3 Gas Water Heater. For
use as potable water heating and space heating.
Smart. Ecient. Endless
Ne pas entreposer ni utiliser d’essence ou
ni d’autres vapeurs ou liquides inflammables
à proximité de cet appareil ou de tout autre
appareil.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ
Ne pas tenter d’allumer d’appareil.
Ne touchez à aucun interrupteur; ne pas vous
servir des téléphones se trouvant dans
le bâtiment.
Appelez immédiatement votre fournisseur de gaz
depuis un voisin. Suivez les instructions
du fournisseur.
Si vous ne pouvez rejoindre le fournisseur,
appelez le service des incendies.
L’installation et l’entretien doivent être assurés
par un installateur ou un service d’entretien
qualifié ou par le fournisseur de gaz.
AVERTISSEMENT
Assurez-vous de bien suivre les instructions données
dans cette notice pour réduire au minimum le
risque d’incendie ou d’explosion ou pour éviter tout
dommage matériel, toute blessure ou la mort.
Certified to
NSF/ANSI 372

Other manuals for Intellihot i200X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intellihot i200X and is the answer not in the manual?

Intellihot i200X Specifications

General IconGeneral
BrandIntellihot
Modeli200X
CategoryWater Heater
LanguageEnglish

Related product manuals