EasyManua.ls Logo

IntelliSense DT-7450 EU DUAL TEC User Manual

Default Icon
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
TBL TBL T T NO EOLCV-NC V+
132
TEST
50%
100%
75%
25%
Select the mounting location.
¹ Wire the unit.
¸ Mount the unit.
ºa Walk-test the sensor.
Mounting Location Guidelines
2.3 m mounting height
Avoid direct or reflected sunlight
Aim sensor away from windows or heating/
cooling devices
Sensor must have a clear line-of-sight to
protected area
Use a small screwdriver to unfasten the housing
latch. Gently pull apart the housings.
Push outward on the PCB latch and lift the PCB
out of the housing.
Slide the wire through the wire channel in the
back housing.
Mount the back housing flat against a wall or in a
corner.
Replace the PCB.
Connect wires as shown using 0.3 - 1.0 mm
2
wire size. Observe proper polarity.
Use Switch 3 to select the appropriate fluorescent
light filter (see Dip Switch Settings chart on the next
page).
Apply power to the unit. Initialization is complete
when the LED stops flashing slowly.
Adjust the microwave range to minimum setting
(25%) by turning the range adjustment counterclock-
wise using a small screwdriver.
Replace the front housing.
Begin walking through the detection area.
- The LED will turn red, indicating an alarm detection.
Increase the microwave range as necessary.
Repeat the items in step 5a until proper detection
range is obtained.
ºb Optional: Walk-test using Zone Finder.
Use a screwdriver to short the test pads.
During the Zone Finder walk-test mode, the LED
turns:
- green for one second for every PIR detection;
- yellow for two seconds for every microwave
detection.
Adjust the microwave range as necessary.
Zone finder mode times out after ten minutes.
Corner
Mount
Wire Channel
Wall Mount
75%
100%25%
50%
DT-7450/7450C EU DUAL TEC
®
Motion Sensor Installation Instructions
Use the Zone Finder mode to identify the PIR and/
or microwave pattern. In Zone Finder mode the red
LED is disabled.
· Separate the sensor housings and
remove the printed circuit board (PCB).
DT-7450
DT-7450C
Question and Answer IconNeed help?

Do you have a question about the IntelliSense DT-7450 EU DUAL TEC and is the answer not in the manual?

IntelliSense DT-7450 EU DUAL TEC Specifications

General IconGeneral
TypeMotion Detector
Current Consumption (alarm)25mA
Operating Temperature-10°C to +55°C
MountingWall or Ceiling
Weight120g
TechnologyDUAL TEC® (PIR + Microwave)
HousingPlastic

Summary

Select Mounting Location

Mounting Location Guidelines

Guidelines for selecting an optimal mounting location, including height and environmental factors.

Separate Sensor Housings and PCB

Mount the Unit

Wire the Unit

Walk-Test the Sensor

Fluorescent Light Filter Selection

Select the appropriate fluorescent light filter using Switch 3.

Unit Initialization and Range Adjustment

Apply power, wait for initialization, and set microwave range to minimum (25%).

Perform Walk-Test and Adjust Range

Walk through the detection area, observe LED, and increase microwave range as needed.

Optional Walk-Test using Zone Finder

Zone Finder Mode Functionality

Utilize Zone Finder to identify PIR/microwave patterns; red LED is disabled.

Initiate and Observe Zone Finder Test

Short test pads to start; LED indicates PIR (green) or microwave (yellow) detection.

Zone Finder Timeout

The Zone Finder mode automatically stops after ten minutes.

LED Indicators and Operation Modes

DIP Switch Settings

Troubleshooting

Red LED Flashing Rapidly

Explanation for rapid red LED flashing: microwave supervision, PIR self-test, or temp. comp. failure.

Detection Patterns

Product Specifications