AC40 Instructions for Use - US Page 10
3.1 Back Panel External Connections Standard Accessories
The back panel contains all the rest of the main connectors (sockets):
Special notes:
The HLS (hearing loss simulator) connector is currently not used. Use the Standard Headphone
and HF Headphone connectors for HLS. This is prepared for future use.
In addition to the standard DD45 headset, four other air conduction transducers may be used
(they all connect to specific outputs on the AC40):
HDA300: High Frequency requires a HF headset.
CIR33 for insert masking: Insert phone CIR33 for insert masking has a limited sound
quality, making it only adequate for masking noise presentation.
EAR-Tone 3A or 5A general purpose insert phone: Insert headphone EAR-Tone 3A or
5A are high quality transducers that may be used instead of the DD45/TDH39. It
improves cross hearing from the normal approximately 40dB of the TDH39 to
approximately 70dB. Masking as well as avoiding over-masking is thus easier with this
type of headphone.
IP30 insert phone is the standard insert phone with same properties as EAR-Tone 3A
Currently FF3/FF4 (both the powered and non-powered) is not used. This is prepared for future
use.
Assistant Monitor: There is always a direct connection through the goose neck microphone to the
assistant wearing a headset connected to the “Assistant Monitor” output.
The LAN connection is currently not used for any application (only internally in production).
Mic 2: Please refer to the section about Patient Communication (Talk Forward and Talk Back).
When using the HDMI output the output resolution will be the saved as on the build in 8,4 inch
display: 800x600.
CD-input: It is required that any attached CD-player has a linear frequency response in order to
comply with the requirements of IEC 60645-2.
USB connections is used for:
PC connection to Diagnostic Suite (the large USB connector)
Direct print
PC-keyboard (for entering client names)
Power
connector
LAN (for
future use)
USB connectors
for printer, PC-
connection &
keyboard
HDMI output
for external
monitor (e.g.
for patient
counceling)
Free Field 1
and 2
(external
amplificatio
Standard
Headphones
DD45/TDH3
9/HDA300
Bone conductor
B81 /B81
1 / 2
Insert
masking
Patient
Response
Switch 1 / 2
Extra Talk
forward
mic., e.g.
for table
External
CD / MP3
input
For
Talk
Back
High Freq.
Left / Right
Amplified
Free Field
outputs
(2x20
watt)
only
Control
output
Assistant
Monitor
Standard
Insert Phone
EarTone 3A /
IP30