EasyManua.ls Logo

Interflex IF-80 Series - Mounting and Cable Routing

Interflex IF-80 Series
13 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Interflex Datensysteme GmbH 7/13
6.5.3 Fastening the Back Panel of the Housing with Cable Feed from the Bottom
Using a level, screw in the back panel of the housing by installing 2 screws in the holes marked (1).
In addition, secure the back panel of the housing by installing a screw in the bottom left hole (2).
For further steps, please refer to: Attaching the IF-800 Outdoor/IF-801 Terminal
10 The drain wire must have an electrical connection to
the back panel of the housing.
12 The cable lug of the blue wire is connected to the
strain relief.
11 Lug for fastening the wall reader with the M2x6 mm
screw
13 Lug for mortise lock
6.6 Important Points to Note Regarding the Mounting
Please observe the following when mounting the terminal:
Do not make any changes to the back panel.
Fastening elements in other places can collide with the circuit
board.