Interflex Datensysteme GmbH 1/23
1 IF-57xx
Thank you for using an Interflex IF-57xx device for recording time and
access data.
2 Scope of Delivery
The following is included in the package:
§ IF-57xx master terminal
§ PoE terminal board
§ 14-pin ribbon cable
§ Metal back panel
§ Accessory bag with mortise lock and material for wall mounting
Please check the completeness and condition of the shipment upon
receipt.
3 Intended Use
The IF-57xx master terminal is used for recording time data as well as for
controlling access and locking devices. The device is designed for fixed
installation in dry rooms. Any other use is not in accordance with the
intended purpose and is therefore not permitted.
4 Storage
The device must be stored in a dry room.
5 IF-57xx Terminal Family
The IF-57xx terminal family consists of three different terminal types with the features described
below.
§ All terminals of this family can read data from state-of-the-art RFID credentials.
§ Power is supplied via a low-voltage power supply unit or PoE (e.g. injector).
IF-5735-0xxx:
§ records time data, such as e.g. IN/OUT bookings or absence reasons.
§ displays account information calculated by the IF-6020/IF-6040 system or provided by SAP.
§ takes over the functions of the time & attendance recording/access control program.
§ writes offline (NetworkOnCard) data onto credentials.
§ allows for connection of an I/O controller (optional, additional hardware required).
§ allows for connection of up to three slave terminals (optional, additional hardware required).
IF-5725-0xxx:
§ records time data, such as e.g. IN/OUT bookings.
§ displays account information.
§ takes over the functions of the time & attendance recording/access control program.
This master terminal:
§ does not write offline (NetworkOnCard) data onto credentials.
§ does not allow for the connection of slave terminals.
§ does not provide access with PIN verification.
§ does not allow for the connection of an interface expander.
LI-95-10307_V2016-10-11 IF-57xx
Zeiterfassungs- und Zutrittsterminal IF-57xx

Other manuals for Interflex IF-57 Series

Question and Answer IconNeed help?

Do you have a question about the Interflex IF-57 Series and is the answer not in the manual?

Interflex IF-57 Series Specifications

General IconGeneral
Display TypeTFT LCD
Operating SystemLinux
Communication InterfacesEthernet, USB, Serial (RS-232)
Protection ClassIP65
Storage Temperature-20°C to +60°C

Summary

Scope of Delivery

Package Contents

Lists the items provided in the IF-57xx package for user confirmation.

Intended Use and Storage

Application and Storage Guidelines

Details device use for time/access control and storage in dry rooms.

IF-57 xx Terminal Family

Terminal Variants Overview

Outlines the IF-5735-0xxx and IF-5725-0xxx terminal types and their core features.

Shielded Cables

Cable Recommendations

Recommends using shielded cables for trouble-free operation.

Risk of Electric Shock

Electrical Safety Precautions

Warns about electric shock and outlines safety measures for installation.

Installation

Installation Steps

Provides a step-by-step guide for installing the IF-57xx.

Laying the Cables

Cable Routing and Electrical Connections

Covers cable routing, electrical connections, and power supply options.

Power Supply and Cables

Power Supply Methods and RJ45 Pinout

Details power supply options and RJ45 patch cable pin assignments.

Cable Types

Recommended Cable Specifications

Lists permissible lengths and recommended cable types for various connections.

Fastening the Back Panel of the Housing

Back Panel Mounting

Instructions for fastening the back panel of the housing to the wall.

Setting the Network Address

Network Address Configuration

Details the factory default IP address and how to change it.

LEDs and Switches

Indicator and Control Overview

Explains the function of each LED and switch on the device.

Service Interface

Service Connection Methods

Describes how to establish a service connection via serial/USB or TCP/IP.

Install Drivers

Driver Installation Procedure

Guides on installing the USB to UART Bridge VCP driver for service interface.

Initial Operation

First Time Setup

Outlines the initial operation steps after installation.

Changing the Controller Password

Password Management

Instructions on how to change the device's password using the passwd command.

Configuring the Network Connection

Network Settings Configuration

Details how to configure network settings using the netpar -x command.

Perform a Restart

Device Restart Options

Explains the commands for warm and cold boots.

Establishing a Telnet Connection

Telnet Connection Setup

Guides on establishing a Telnet connection using factory default credentials.

Touch Screen and Proximity Sensor

User Interface Features

Details touch screen operation and proximity sensor functionality.

Technical Specifications

Device Specifications Overview

Provides detailed electrical and general technical data for the IF-57xx.

Accessories

Optional Accessories List

Lists optional accessories available for the IF-57xx.

Interface Expansion

Interface Expander Mounting

Details the mounting process for the interface expander.

Connections

Interface Expander Connections

Explains the connections for the interface expander board.

Connection to IF-57 xx

Connecting the Interface Expander

Describes how to connect the interface expander to the IF-57xx master terminal.

Connection of an Interface Expander to an IF-57 xx Terminal

Expander to IF-57 xx Connection Diagram

Illustrates the connection of an interface expander to an IF-57xx terminal.

Technical Specifications of the Interface Expander Board

Interface Expander Specifications

Provides technical data for the interface expander board.

Serial Expansion

Serial Expander Mounting

Details the mounting process for the serial expander.

Connection of an External Device to an IF-57 xx Terminal

Connecting External Devices

Explains connecting devices like barcode readers via the serial expander.

Connection to IF-57 xx

Serial Expander to IF-57 xx Connection

Describes connecting the serial expander to the IF-57xx master terminal.

How to Connect a Barcode Reader

Barcode Reader Connection

Details connecting a barcode reader to the serial expander.

Technical Specifications

Serial Expansion Specifications

Provides technical data for the serial expansion interface.

Spacer

Spacer Mounting

Instructions for mounting the IF-57xx spacer.

Laying the Cables

Spacer Cable Management

Guidance on laying cables with the spacer.

Large Spacer

Large Spacer Application

For devices using less flexible or thicker cables.

Installation

Large Spacer Installation

Details the mounting process of the IF-57xx onto the large spacer.

Mounting

Large Spacer Mounting Details

Provides specific mounting steps for the large spacer.

Spacer and Variants

Large Spacer Specs and WLANCamera Models

Covers large spacer data and available IF-57xx WLAN/Camera models.

Disposal

Device Disposal Procedures

Instructions on how to properly dispose of the device as electronic waste.

Open Source Program Packages

Open Source Licensing Information

Notes the use of open source packages and licensing terms.

Related product manuals