Interflex Datensysteme GmbH 5/23
For devices of the series IF-57xx, the flexible patch cable must run through an empty
tube to the installation site when flush-mounted to ensure that the line length can be flexibly adjusted!
9.3 Cable Types
Only use the cable types listed below.
No.
Permissible
Length
Recommended Cable Type
1 230 VAC power supply to optional adapter 3 x NYM 1.5 mm²
2 Low-voltage cable for supplying power to IF-57xx J-Y(ST)Y 4 x 2 x 0.6 mm² or
Flex JZ 3 x 0.75 mm²
3 Ethernet/patch cable to hub/switch 100 m Ethernet twisted pair cable
(Cat5)
4 Ethernet/patch cable with/without PoE hub/switch to
IF-57xx
100 m Ethernet twisted pair cable
(Cat5)
5 Ethernet/patch cable from hub/switch to controller
IF-4070
100 m Ethernet twisted pair cable
Flexible patch cable (Cat5)
6 RS485 BUS 1,200 m J-Y(ST)Y 4x2x 0.6 mm²