Chapter 5: Menu reference
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual 127
1.2.5 Walk test
The Walk test menu allows testing of zones. The zone passes the test when
switching its state from normal to active, and then from active to normal. In walk
test mode each zone state change is signalled by the keypad buzzer or an
internal bell.
See also “Walk test” on page 80 in Chapter 3 “System functions”.
1.2.5.1 Start
Run the engineer walk test.
See “Engineer walk test” on page 80 for details.
1.2.5.2 Walk test opts
The Options menu allows setting up the following walk test options.
1.2.5.2.1 Use internal siren
If the Use internal siren option is set to Yes, each activation of a tested zone is
signalled by the internal siren.
1.2.5.2.2 Use buzzers
If set to Yes, each tested zone activation is signalled by keypad buzzers.
1.2.5.2.3 Log untested
If the Log untested option is set to Yes, untested zones are recorded in the
system log.
1.2.5.2.4 Zone tamper
If the Zone tamper option is set to Yes, the zone tamper is included into the walk
test.