Chapter 8: Regulations
Advisor Advanced ATSx500A(-IP) Installation and Programming Manual 305
8.4.4 Forced set: Off
8.4.7 AS fault retry: 15 minutes
8.4.8 AS user retry: Disable
See also the appropriate RAS manual for more details.
EN 50136 policy
Required settings:
“9.1.n.7 Retry count”: 1
“9.1.n.8.3.2 Heartbeat time”: According Table 30 below.
“9.1.n.8.3.5 Freq. HB time”: According Table 30 below.
“9.3.n.7.1 Firewall”: Yes
“9.3.n.7.2 Reply on PING”: No
“9.3.n.7.6.1 Firewall”: Yes
“9.3.n.7.6.2 Reply on PING”: No
“9.3.n.9 Encryption”: Yes
“9.4.3 Encryption key 1” must be set.
See also “Transmitter polling interval requirementsbelow.
Transmitter polling interval requirements
Transmitter polling interval must be set according to specified requirements for
different alarm transmission systems (ATS). Table 30 below lists all required
settings for the appropriate standards and diallers.
Table 30: Transmitter polling settings
Standard and
category
Required
polling interval
Comm. path and
dialler
Option
Required
value
EN 50136:2012
SP2
25 h
PSTN via ATS7700
and GPRS (backup)
via ATS7310
1.2.6.n.3 Period
24
SP3
30 min
IP built-in, or GPRS
via ATS7310
9.1.n.8.3.2 Heartbeat time
00:29'00
SP4
3 min
IP built-in, or GPRS
via ATS7310
9.1.n.8.3.2 Heartbeat time
00:02'30
SP5
90 s
IP built-in
9.1.n.8.3.2 Heartbeat time
00:01'00
SP6
20 s
IP built-in
9.1.n.8.3.2 Heartbeat time
00:00'10
EN 50136:2010
ATS2 (T2),
ATS3 (T2)
25 h
PSTN via ATS7700
and GPRS (backup)
via ATS7310
1.2.6.n.3 Period
24
ATS4 (T3)
300 min
IP built-in, or GPRS
via ATS7310
9.1.n.8.3.2 Heartbeat time
04:55'00