Chapter 5: Menu reference
260 Advisor Advanced ATSx500A(-IP) Installation and Programming Manual
In case a few areas have the same account numbers, and “9.1.n.9 OP/CL report
option on page 262 is set to Yes, a special operation takes place for SIA/XSIA
reporting of opening/closing depending on the area modifier setting (see
“9.1.n.8.1 XSIA”, page 261).
Area modifier off: Closing is reported when all areas with the same account
number have been set. The area that was set last is reported. The first to
disarm sends the opening signal for the area to be opened.
Area modifier on: Opening and closing signals are reported separately. The
Area Modifier is used to identify the correct area.
Note: System events, as well as Area 1 events, are always reported using
Account 1.
9.1.n.5.m Select area
1 Area 1
> <
Set account numbers for each area.
9.1.n.6 Mode
6 Mode
>Primary CS<
The following modes are available for CS.
Primary CS: The primary central station must unconditionally receive all
addressed events.
Backup CS: The central station can be a backup CS for the previous CS in
the central station list (see “9.1 Central stationon page 258). This means
that the panel reports to this central station only if the primary CS reporting
fails.
For example, if CS 1 and CS 2 are primary CS, and CS 3 and CS 4 are backup
CS, it means that CS 1 has no backup, CS 3 is a backup central station for CS 2,
and CS 4 is a backup for central station 3.
See “Reporting principleson page 84 for more information.
9.1.n.7 Retry count
7 Retry count
>1<
The Retry count value is the number of retries to make a successful call to the
central station. If the limit is reached, the FTC is generated.
The counter is zeroed when a new event occurs in Global FTC condition. See
“Failed to communicate (FTC)on page 86 for more information.
The value ranges from 0 to 14. The default value is 1.

Table of Contents

Other manuals for Interlogix ATS3500A-IP-MM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Interlogix ATS3500A-IP-MM and is the answer not in the manual?

Interlogix ATS3500A-IP-MM Specifications

General IconGeneral
BrandInterlogix
ModelATS3500A-IP-MM
CategorySecurity System
LanguageEnglish

Related product manuals